User's Manual

Proprietary and Confidential 2006.02.08
6
2.3 Mark the disk (electromechanical meters only)
Complete the following steps if the disk is not already marked with a factory or other ½” W x ¾” H mark.
1. Remove the meter nameplate and set the original nameplate mounting screws aside. Note: New, longer screws will
be required to remount the module under the nameplate for the GE I-70 meters.
2. Align the disk marking template on the disk with the upper left corner of the template opening aligned with the left
side of the index mark on the disk as shown in Figure 3.
3. Fill in the ½” W x ¾” H gap formed by the template with the disk marking paint pen. Be careful to avoid smearing
the wet paint mark when removing the template from the disk.
Note: Do not substitute the paint pen with any other type of marker as this may cause the mark to not be correctly
detected.
Figure 3: Disk Marking Template Aligned on Disk