3.5 Programming Error Codes
When attempting to send the configuration to the NC-90, error codes may appear under certain
conditions.
110 – No communication with the TUNet device.
Check the following:
1. Check correct device IP. The default is 24.25.26.28 for dynamic address programming.
2. Check network cable connections between the DT-400 and the TUNet device.
3. Check DT-400 is in the correct network configuration. For dynamic address configuration, choose
option 1 in the sysadmin account. For reprogramming a device that has already been pre-
configured with a static address, the DT-400 will have to be configured to match the network setting
of the device. See section Reprogramming Devices with Static Addresses.
4. Check that the TUNet device is powered by seeing if the status LED is on.
5. The NC-90 device may have timed out and is restarting. This will occur 6 minutes after power is
first applied. It is recommended to disconnect power to the stick for 20 seconds and reapply.
255 – TUNet Device has started but is not ready.
The NC-90 has not completed its boot up cycle. Try again in 10 seconds.