User's Manual

Page 6 Tantalus Systems Corp.
Released: 2010/1/31
3.1 Programming Quick Start
Note: Ensure that the date, time, and time zone have been set under the sysadmin account before first
use of the DT-400. Refer to section 3.3.4 for details.
EQUIPMENT REQUIRED
DT-400 laptop
Ethernet Cable
NETWORK SETTINGS PROVIDED BY SYSTEM ADMINISTRATOR
Dynamic IP Scheme Static IP Scheme
Time Zone Offset ________________
IPNM Server Address ________________
IPNM Port Number __________________
Time Zone Offset ________________
IPNM Server Address _______________
IPNM Port Number _________________
IP address for Device _______________
Netmask _________________________
Gateway _________________________
DNS ____________________________
*** Note the IPNM (IP Network Manager) server address is typically at the same address as the
Tantalus Network Server.
PROGRAMMING QUICK START PROCEDURE
1. Start the laptop and log in as “tunet”.
2. Plug the network cable into NC-90 port and the other end to the laptop.
3. Apply power to the NC-900 Network Controller.
4. Wait approximately 90 seconds until the solid orange status light on the NC-90 changes to either
solid red (factory default / never programmed), flashing orange (previously programmed) or flashing
red (previously programmed but no network connection found).
5. Proceed to configure the TUNet NC-90 as explained in the following sections.
Note: The TUNet NC-90 reboots every 5 minutes if it is not communicating with a Tantalus Network
Server. This is indicated by the status light changing to flashing red 6 minutes after initial power up. This
may result in an unsuccessful programming attempt. It is recommended to remove power for 20
seconds and reapply. The device will then go through the normal startup cycle.