Auto Power Off
The scale is designed with an auto power-off function for energy efciency. If the same reading is displayed for
more than 10 minutes the scale will automatically turn off.
Battery replacement
If “Lo” appears in the display when attempting to weigh, replace the battery. (following previous instructions)
Trouble shooting
• Thepowerdoesn’tturnon.
Insert 2 new size AAA (“R03” or “24F” ) batteries. Be sure that the polarity of the batteries is set properly.
•“Err6”or“Err7”appearsonthedisplay.
The scale needs to be repaired. Please contact your retailer.
• “Err1”or“Err8”appearsonthedisplay.
Place the container or item(s) only after 0 g/0.00 oz is displayed.
• Thescaledoesnotsettomicromode/Mmarkdisappearswhileoperating.
Minimum display is 1 g/0.05 oz when the total weight on the tray is 1000 g/35.28 oz or more.
Press
Micro
TARE
again after removing the weight.
• AlthoughMicroModewasselected,theweightofsomethinglessthan200g/7.05ozcannotbeshownin
0.1g/0.01ozincrement.
Has the scale display ever shown 0 g after pressing
Micro
TARE
during additional measurement? If the answer
is “Yes”,
that means the total weight on the scale has reached/exceeded 1000 g/35.28 oz. Once the total weight reached/
exceed 200 g/7.05 oz, the scale increment will automatically change to 0.5 g/0.02 oz even
if
Micro
TARE
is pressed
during additional measurement. By the same token, when total weight reached/exceeded
1000g/35.28oz, the
increment will change to 1g/0.05oz.
To reset the scale to Micro Mode, simply remove all the materials from the tray, then press
Micro
TARE
to show
0.0 g/0.00 oz.
Specification
g version g/oz version
Capacity 2000 g 2000 g / 70.5 oz
Graduation
Normal measurement mode 1 g 1 g / 0.05 oz
Micro mode
0 – 200 g 0.1 g
200 – 1000 g 0.5 g
0 – 200 g 0.1 g
0 – 7.05 oz 0.01 oz
200 – 1000 g 0.5 g
7.06 – 35.28 oz 0.02 oz