User's Manual
61
Compatible Models
RTR-51
・
RTR-52
・
RTR-53
・
RVR-52
・
TR-51A
・
TR-52
・
TR-71S
・
TR-72S
Recording Capacity 16 units at full data 16,000 readings × 16 = 256,000 readings
Can hold up to 250 downloading sessions
Functions Downloading Data (possible to display results of upper and lower
limit check after downloading)
・
Display Saved Data Graphs
・
Display Highest and Lowest Temperature・Set Recording Start
for Remote Data Loggers
・
Delete Stored Data (one reading
・
all readings)・Monitor Current Temperature・Search for Remote
Units
LCD Display Operation Menu・Graph Display・Low Battery Life Warning・
Calendar and Clock・Contrast Adjustment・Backlight
Power TTwo AAA Alkaline Batteries (LR03)・Can use rechargeable AAA
Ni-Cd or Ni-MH 1.2V batteries
・
Special AC Adaptor (AD-0604)
Battery Life 100 hrs under Continuous Operation
Auto Power Off Function (Turns unit off after 3 minutes of non-use)
Data Backup Approx. 1 year with switch off Data erased if all battery power is lost
Wireless Method ETSI EN300-220
Transmission Distance Up to 100 meters (May vary with conditions)
Interface
Communication Speed Special Short Wave Radio Type: approx. 2,000bps / min
(with data logger)
Modular Jack:
Serial Communication(RS-232C) 19,200bps (with computer)
9,600bps (with data logger)
Optical Communication: 2400bps (with data logger)
Interface
Communication Time Data from RTR-57C to Computer:
One Full Logger’s Data ~ 25 sec.
Data from RTR-51 / 52 / 53 / RVR-52 to RTR-57C via wireless:
One Full Data~420sec.
Data from TR-7 Series to RTR-57C via cable:
One Full Data ~ 50sec.
Data from TR-5 Series to RTR-57C via optical:
One Full Data ~ 160sec.
Dimensions H 125mm x W 58mm x D 25.5mm (excluding protruding part)
Antenna Length: 20mm-105mm (fully extended)
Weight Approx. 125g. (Including 2 AAA Alkaline batteries)
Operating Conditions Temperature: 0 to 50℃
Humidity: Less than 90% RH (Without dew condensation)
Specications for