User's Manual

27
Remote Unit Properties (Remote Unit Info List)
View Remote Unit Info for the unit(s) selected from the Remote Unit List.
Unit Type ---------------The type of unit (RTR-51/52/53 or RVR-52) for the selected
Remote Unit(s) will be displayed.
Group Name ----------The Group Name appears.
Frequency Channel -The Frequency Channel for communication between the Base
Unit and the Remote Units appears.
Remote Unit Name --Displays the name of the selected Remote Unit.
Relay Route Name --Displays the Name of the Relay Route via which the Remote
Units communicate.
Relay Route Frequency Channel Displays the Frequency Channel of the Relay
Route via which the Remote Units communicate.
Relay Unit Number --Displays the No. of the Relay Unit via which the Remote Unit is
connected.
CH1 Upper Limit -----Displays the Upper Limit set in [Monitoring / Warning Monitoring]
for Warning Report.
CH1 Lower Limit -----Displays the Lower Limit set in [Monitoring / Warning Monitoring]
for Warning Report.
CH2 Upper Limit*1 --Displays the Upper Limit set in [Monitoring / Warning Monitoring]
for Warning Report.
CH2 Lower Limit*1 --Displays the Lower Limit set in [Monitoring / Warning Monitoring]
for Warning Report.
Monitoring Interval ---Displays the currently set Monitoring Interval.
Auto Download Interval Displays the currently set Auto Download Interval.
*1ȇFor RTR-53 only
Settings Area
There are four different types of Settings windows: [Download Data] Tab,
[Start Recording] Tab, [Monitoring / Warning Monitoring] Tab, and [Auto
Download] Tab.
Main Unit Info
Open the [Main Unit Info] in the [Help] menu to view the Version Info for the currently
connected RTR-50 Unit.It is also possible to view the battery condition in the RTR-50
Unit.