User's Manual

Speci cations
Temperature/
Humidity Sensor
(External)
THA
-
3001 HHA
-
3151(High-Precision Type)
Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance
Measurement
Channels
Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch
Units of
Measurement
°C, °F %RH °C, °F %RH
Measurement
Range (*1)
0 to 55 °C 10 to 95 %RH
-
30 to 80 °C 0 to 99 %RH
Accuracy ±0.5 °C
±5 %RH
[at 25 °C, 50 %RH]
±0.3°C
[at 0 to 50 °C]
±0.5°C
[at all other
temperatures]
±2.5 %RH [at 25 °C, 10 to 85 %RH]
±4.0 %RH [at 25 °C, 0 to 10 % or 85
to 99 %RH]
At temperatures other than 25 °C and
0 °C, add ±0.1 %RH per degree of
difference from 25.
Humidity Hysteresis: ±1.5 %RH or
lower (*2)
Measurement
Resolution
0.1 °C 1 %RH 0.1 °C 0.1 %RH
Responsiveness Response Time (90%): Approx. 7 min.
Response Time (90%):
Approx. 7 min.
Response Time (90%):
Approx. 20 sec.
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*4) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
Communication
Interfaces
Wireless Communication (Short Range Radio Communication)
FCC Part15 Section247 / IC RSS
-
210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
USB Communication"
Wireless Transmission
Range
Approx. 150 meters (500 ft) if direct and unobstructed
External Alarm
Terminal
Output Terminal: Open Drain Output
(Voltage when OFF: DC less than 30V / Current when ON: less than 0.1A / Resistance when ON: about
15Ω)
Power AC Adaptor (AD
-
0638 or AD
-
0638-C), AA Alkaline Battery (LR6) x 4
Battery Life (*5) Approx. 2 days (batteries only without AC adaptor)
Dimensions
H 96 mm x W 66 mm x D 46 mm (excluding protrusions and sensor)
Antenna Length: 60 mm
Weight Approx. 220 g (including battery, excluding sensor)
Operating
Environment
Temperature: 0 to 45 °C
Humidity: 90 %RH or less (no condensation)
Compatible Base
Units
RTR
-
500, RTR
-
500NW/500AW, RTR
-
500DC
*1: Make sure to use the data logger within the operating environment as listed in the speci cations.
*2: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%,
sensor hysteresis may uctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to nor.
*3: Stated value is the measurement accuracy of the CO2 sensor when Auto Calibration is operating properly. A change in atmospheric
pressure directly in uences the reading of CO2, which can cause measurement errors; a decrease in pressure by 10hPa result.
*4: Only “Endless” is available when using RTR-500W for Windows.
*5: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and
the battery performance. All estimates are based on operations carried out with a new battery and are in no way.
The speci cations listed above are subject to change without notice.
Cautions about using the Temperature/Humidity Sensors
If extremely severe temperature changes occur, the humidity measurements may appear
abnormal. Once the sensor's temperature becomes stable, the measurements will return to
normal.
Do not connect the sensor to any data logger other than those speci ed by T&D Corporation.
Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy
and cause damage or malfunction.
When the sensor is not to be used for a long period of time, please store it at normal
temperature and humidity.
Do not use the sensor on the human body.
Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under
normal operational conditions. We suggest changing the THA-3001 after about one year of use.
If the sensor is being used in a bad environment (smoky or dusty places) it may be necessary to
change the sensor sooner.
This sensor is not water resistant. Do not allow the sensor to become wet. If the sensor gets
wet, immediately remove the sensor from the unit and wipe it with a clean cloth as soon as
possible. Then allow the sensor to dry in normal room temperature before using it again.
Initial Settings
Recording Conditions Recording Mode: Endless
Recording Interval: 10 min.
LCD Display Pattern Alternating Display
Options
Temperature/Humidity Sensor: THA-3151 High Precision Temperature/Humidity
Sensor: HHA-3151
Measurement Range: Temperature: 0 to 55°C, Humidity:
10 to 95 %RH
Measurement Resolution: Temperature: 0.1°C, Humidity:
1 %RH
Accuracy: Temperature: ± 0.5°C,
Humidity: ± 5 %RH (at 25°C and 50%RH)
Response Time (90%): Approx. 7 min.
Cable Length: 1.5 m
Measurement Range: Temperature:
-
30 to 80°C,
Humidity: 0 to 99 %RH
Long Term Stability: ± 1%RH/yr, ± 0.1°C/yr
(Do not expose to condensation, dampness, dust,
corrosive gases or organic solvents.)
Cable Length: 1.5 m
Sensor Extension Cable: TR-1C30 Wall Attachment: AT-76K
Possible to use up to three extension cables
per sensor
Compatible Sensor: THA
-
3001, THA
-
3151, HHA
-
3151
Temperature Durability:
-
25 to 60°C
Material: Vinyl Coated Electrical Wire
Cable Length: 3 m
Material: Aluminum
Accessories: Screw x 2
Explanation of Symbols
Explanation of Warning Symbols
DANGER
These entries are actions that, if taken, may cause serious personal physical
damage or death.
CAUTION
These entries are actions that if taken may lead to physical injury or damage to
persons or things.
Explanation of Picture Symbols
Denotes an important
warning or caution.
Denotes a forbidden
action.
Denotes an action that
should be carried out.
DANGER
To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and accessories.
Do not use the unit in any environment that is exposed to chemicals and harmful gases. Doing
so may cause corrosion and/or other danger to the unit. Also, coming in contact with hazardous
substances may cause bodily harm to the user or people nearby.
This Unit is not waterproof. If water or a foreign object enters the case, immediately remove
batteries and stop using it.
Do not insert or replace batteries or sensors with wet hands.
This unit has been designed for private and/or industrial use only. It should not be used in
situations where strict safety precautions are necessary such as with medical equipment, or in
systems directly or indirectly connected with human life or well-being.
We shall not guarantee the unit's operation if it has been connected to a PC using a USB hub or
a USB extension cable.
Do not drop or expose the unit to a strong impact.
Do not cut or process the sensor cables. Also, do not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static electricity from your body by
touching metal around you (such as a door knob and window frame) before touching the unit.
Place and store the unit and accessories out of the reach of children.
Further, T&D is not responsible for any damage, malfunction or trouble, whether direct or
indirect, caused by the use of our products.
Do not use any power or sensors other than those speci ed by T&D Corporation.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noise, immediately
remove the batteries and stop using it.
CAUTION
Do not place or store in the following areas:
Areas exposed to direct sunlight
Areas subject to high temperatures such as near re or heating equipment
Areas exposed to static electricity
Areas exposed to strong magnetic elds
Areas exposed to dampness
Areas subject to condensation or wet areas
Areas exposed to excessive vibration
Areas exposed to excessive smoke, dust or dirt.
CAUTION
Other Precautions
Use the unit in the speci ed operating environment. Do not use it for any purpose other than for which it was
designed.
Condensation may occur inside the case when a unit is moved from one environment to another where there is
a great difference in temperature. Be careful to avoid condensation.
Do not use the unit in wet areas or places exposed to water such as bathroom.
Do not insert any foreign objects into any of the units' jacks.
If the unit gets dirty, wipe it with a clean cloth.
Please note that this Introductory Manual has been written based on the presupposition that details about
set-up of any necessary equipment to enable network connection have already been taken care of by the
user and that connection has been con rmed as workable. T&D Corporation shall not be responsible for any
damages which a contractor, a user or a third party may suffer, whether direct or indirect, due to the inability to
communicate or use communication devices.
CAUTION
Notes and Precautions for Installing Wireless Communica-
tion Devices
When installing wireless communication devices take special care in selecting locations so as to ensure
proper communication. Note that even after a successful installation, due to changes in environmental
conditions, communication errors may occur when restarting the system.
As far as possible, try to keep wireless communication devices away from metals and set them up in high
unobstructed positions.
Please take note that in many instances, walls, oors, stairs, fences and desks will contain metals. In order to
carry out communication between indoor and outdoor units, please locate indoor units near a window so that
radio waves can be easily transmitted.
Please install the Unit more than 30 cm away from walls or boards containing metal.
If the Unit is placed in a metal container such as a freezer or refrigerator, the possible wireless communication
range will be shortened. In most cases radio waves are transmitted via doors and door openings so place the
Unit as near to doors as possible.
As far as possible, keep the Unit away from noise-emitting sources.
Equipment such as some industrial instruments, electronic devices or uorescent lamps generate noise. Please
place the Unit more than 1 meter away from such devices.
Please place the Unit more than 1 meter away from computers and other devices which emit noise.
Keep all wires as far away from wireless communication devices as possible. Please be careful about placing
near any wiring or cables such as power supply cables, telephone wires or LAN cables.
Objects which contain lots of water, such as plants or soil, absorb radio waves. We highly recommend that
such materials should not be placed between or near wireless communication units.
When measuring temperature in a greenhouse it has been reported that as plants grew, communication errors
also increased.
Do not place the Unit directly on the ground.
Do not place Units which are using the same communication frequency channel in the same area. If the same
channel is used for multiple units not only will more communication errors occur, but battery life will also be
shortened.
If there is a possibility that Units with the same frequency channel will be in wireless communication at the
same time, please make sure to make changes to the frequency channels so they are not the same.
Getting Ready to Use External Alarm Terminal
It is possible to connect an external device such as siren or lamp to the RTR-576.
Please make sure to check speci cation details of the external alarm terminal before
purchasing or getting an external device ready for connection.
About the External Alarm Terminal (EXT ALM)
Enabling
Warnings
Warning Output
(Enable / Disable)
Internal Pull-up: 3V 100 kΩ
Maximum Input Voltage: 30V
GND
Warning Output
(OUT)
Output Terminals
(Warning Output)
Open Drain Output
Voltage when OFF: DC less than
30V
Current when ON: less than 0.1A
Resistance when ON: 15Ω
GND
The connection between and decides whether Warning Output
is enabled or disabled. If a warning condition occurs while Warning
Output is enabled, a connection between
and will be
established and a warning will be output.
Enabled Disabled
About the Compatible Connector
The JST Connector PAP-04V-S is compatible with the external alarm terminal. For questions
concerning sales of the connector, please directly contact JST Mfg. Co., Ltd.
http://www.jst-mfg.com/
Auto Calibration Function for CO2 Sensor Accuracy
What is "Auto Calibration" ?
Auto calibration is a function designed to enable long-term accurate measurements by
adjusting the lowest CO2 concentration measured in a certain period of time to the set
standard measurement in the air (atmospheric CO2 levels of 400 ppm).
The factory default setting for auto calibration is enabled.
Turning ON and OFF Auto Calibration
Turn off auto calibration (*1) when continuously measuring in an environment where
measurements are greatly different from the standard 400ppm CO2 concentration. Then, to get
more accurate measurement results, place the RTR-576 in general atmospheric environment
and periodically check if the CO2 concentration gets closer to 400ppm or not. If not, we
recommend that you carry out manual calibration (*2).
*1: To change settings, it is necessary to download "Adjustment Tools" application (free) from our website. Detailed info
can be found below.
*2: Manual calibration is expected to be performed no more than once a month. Operational procedures and other
reference info can be found below.
See:
For RTR-500 / 500AW / 500NW
[
Operation Guide] - [How to Use] - [Other Useful Functions] Menu
For RTR-500DC
[RTR-500DC Settings Utility Help] - [ How to Use] - [Basic Settings] - [Remote Unit Registration] Menu
Important Notices and Disclaimers
In order to properly use this product, please carefully read all documents that accompany the product
before using. T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this
product or with your computer that is caused by the improper handling of this product and will deem such
trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty.
All rights of the attached documents belong to T&D Corporation. It is prohibited to use, duplicate and/or arrange
a part or whole of the attached documents without the permission of T&D Corporation.
Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other
countries.
Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and/
or other countries.
All registered trademarks, company names, product names and logos mentioned herein or for products being
used are the property or registered property of T&D Corporation or of their respective owners.
• Speci cations, design and other contents outlined in the attached documents are subject to change without
notice.
Please follow the safety precautions outlined in the attached documents carefully. We cannot guarantee nor are
we responsible for safety if this product is used in any manner other than was intended.
On-screen messages in the attached documents may vary slightly from the actual messages.
Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear
explanations in the attached documents.
T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
Accompanying documents cannot be reissued, so please keep them in a safe place.
Please read the warranty and provisions for free repair carefully.
Compliance Information
FCC Statement
This device complies with Part 15 of the Federal Communications Commission (FCC) rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modi cations not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Note about Antenna Usage
This device has been designed to operate with the supplied antenna only. Use of any other antenna is
strictly prohibited.
IC Statement
This device complies with RSS-210 of the Industry Canada (IC). Operation is subject to the following
two conditions: (1) This device may not cause harmful interference; and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Ce dispositif est conforme à la norme RSS 210 d’Industrie Canada.
L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire
de brouillage et (2) l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu,
même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
Wireless products cannot be used in countries other than where those products have been approved for
use, according to that country's wireless regulations.
Important Notices
Wireless products cannot be used in countries other than where those products have been approved for
use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of these products, nor
be liable in any manner for legal consequences stemming from the usage of these wireless products in
unapproved areas.
For product information or questions contact us at:
817-1 Shimadachi Matsumoto, Nagano 390-0852 JAPAN
Fax: +81-263-40-3152 E-mail: support@tandd.com
http://www.tandd.com/
We have opened an English Website for your convenience. Here you can nd information about our
company, news, products, upcoming events, software and Introductory Manual downloads, as well as,
ther support. Please stop by and see what we have to offer.
Wireless CO2 Recorder RTR-576 Warranty
Guarantee Period
1 year from date of purchase
Date of Purchase
Customer's name
Address
Phone No.
Distributor's name
Address
Phone No.
Object of Repair
Main Unit (excluding sensors and any other options.)
Method of Repair
Send in for Repair
Provisions for Free Repair
1. If the unit does not work properly despite the fact that the customer used it properly and in line with the manual, the Unit shall be
repaired free of charge through the distributor which sold the unit.
2. If the customer requests free repair because of trouble within the warranty period, bring or send the unit along with the warranty to
the distributor.
3. If you have moved after purchasing, or there are dif culties contacting the distributor from which you purchased the unit, please
contact T&D directly for service.
4. Free repair is not available in the following cases even though it is within the warranty period:
1. Trouble or damage was caused by careless operation, natural disaster, re, public pollution, or use of a power source other than
speci ed.
2. If repair, adjustment, disassembly or modi cation of the unit has been carried out by a person other than a T&D authorized
engineer.
3. Trouble or damage was caused by transportation, movement or dropping of the unit after purchase.
4. Failure to submit the warranty or failure to ll in all items required in the warranty.
5. The warranty cannot be reissued.
This warranty only promises customers free repair within the period and conditions clari ed in this warranty. Therefore, the
customer's legal rights will not be limited by this warranty. For further information on repair and other service questions after the
termination of the warranty period, contact your distributor.