700 MXP • Highly integrated stand-alone executive video system • Integrated 20” LCD wide screen • Integrated High Definition camera • Simple user interface • Optional MultiSite capabilities • Optional presentation and dual video stream capabilities • Headset connection for privacy • Standards-based embedded encryption (AES & DES) • Protection against network interruptions with automatic Downspeeding and IPLR Software version F5 D13954.
Trademarks and Copyright We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or otherwise, without the prior written permission of TANDBERG.
Disclaimer & License Agreements We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php The information in this document is furnished for informational purposes only, is subject to change without prior notice, and should not be construed as a commitment by TANDBERG. TANDBERG reserves the right to amend any of the information given in this document in order to take account of new developments.
Disclaimer & License Agreements, Patent Information TANDBERG 1700MXP USER GUIDE Disclaimer CMU-SNMP California. All rights reserved. The information in this document is furnished for informational purposes only, is subject to change without prior notice, and should not be construed as a commitment by TANDBERG. Copyright © 1988, 1989, 1991, 1992 by Carnegie Mellon University All Rights Reserved This code is derived from software contributed to Berkeley by Stephen Deering of Stanford University.
Operator Safety / Environmental Issues We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php For your own protection, please read the overleaf safety instructions completely, before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators.
Safety Instructions For your protection please read these safety instructions completely before you connect the equipment to the power source. Carefully observe all warnings, precautions and instructions both on the apparatus and in these operating instructions. Retain this manual for future reference.
Environmental Issues Thank you for buying a product which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (chemicals, toner, gas, paper). Our products are low energy consuming products. TANDBERG’s Environmental Policy Environmental stewardship is important to TANDBERG’s culture.
Finding the Information You Need We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php Thank you for choosing TANDBERG! The TANDBERG 1700MXP has been designed to provide you with many years of safe, reliable operation. Your approach to the 1700MXP documentation depends on what you want to do and how much you already know. This User Guide has been divided into several separate sections.
Disclaimer & License Agreements 1700 Disclaimer & License Agreements, Patent Information............4 Disclaimer..................................................................... 4 License Agreements....................................................... 4 Agfa ............................................................................. 4 CMU-SNMP . ................................................................. 4 Dropbear - an SSH2 server ............................................ 4 eCos.........
Call Handling Access Codes.................................................................................. 25 About Access Codes.................................................... 25 Making Calls when Prompted for an Access Code.......... 25 Making Point-to-Point Video & Telephone Calls Manually...... 26 Making Video Calls Manually........................................ 26 Making Telephone Calls Manually................................. 26 Choosing Between Video and Telephone Call.................
System Name Settings................................................................. 63 Autoanswer..................................................................................... 64 Phone Book Settings..................................................................... 65 External Services........................................................................... 66 Permissions.................................................................................... 67 Access Codes.........................
Getting Acquainted with the System We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php Before you start using the system we recommend that you take your time to read through this section of the User Guide to get you up and going. This section outlines how to connect the system and the basic operating principles. Important video and sound matters are also covered.
Getting Acquainted with the System Preparing for Use TANDBERG 1700 MXP USER GUIDE Viewing Angle Adjustment Connecting Cables Connect cables as shown. DVI-I for PC presentations Tilt the display manually to get a better viewing angle. Audio / Line In for PC sound Connect the video system to your LAN RS-232 (for adminstrator use) Camera Matters The Lens Cap is held in place by a magnet.
Getting Acquainted with the System Waking Up the System TANDBERG 1700 MXP USER GUIDE Waking Up the System Wake up the system by picking up the remote control. The system will now produce the Welcome screen. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The IP number and the system name are displayed in the upper right corner. The IP Number is the dial-in number of the system.
Getting Acquainted with the System Operating Principles TANDBERG 1700 MXP USER GUIDE Basic Menu Navigation Rules up the remote control to wake up the system or Pick press OK to display the main menu line. The menu line will be displayed. the horizontal Arrow keys to navigate in the menu line Use and press OK to enter a submenu. Camera Presets Camera Presets Snapshot Snapshot Touch tones Use the Arrow keys to navigate in the submenu.
Getting Acquainted with the System Camera Adjustments TANDBERG 1700 MXP USER GUIDE About Camera Adjustments The focus of the camera is adjusted manually by rotating the ring as pointed out in Preparing for Use. The camera can be tilted manually as explained on the same page. Adjusting the Camera Press OK and navigate to the Camera Control icon. Click OK to enter the Picture Control options and navigate to the Picture Control icon.
Getting Acquainted with the System The icons Appearing on the Screen TANDBERG 1700 MXP USER GUIDE About the Icons Microphone Off To help you immediately realise the present status of important actions, states, and events taking place, there is a number of icons appearing on the screen, whenever applicable. This indicator is shown when the microphone is turned off. Press the Mic off button of the remote control to toggle between On and Off.
Getting Acquainted with the System Selfview TANDBERG 1700 MXP USER GUIDE About Selfview Using Selfview Outside a Call In this User Guide, the term Selfview means the outgoing image. In a normal call using the main camera, this is the image of yourself. The Selfview button toggles the images between Far End, Selfview and Dual Video Stream (if applicable).
Getting Acquainted with the System Screen Layout TANDBERG 1700 MXP USER GUIDE About Screen Layout The layout of the screen can either be shown as Picture In Picture (PIP) or Picture Outside Picture (POP) when displaying more than one video image. For widescreen monitors, POP is recommended. The behavior of the Layout key depends on the Picture Layout setting in Control Panel > Screen Settings.
Getting Acquainted with the System Local PC Display TANDBERG 1700 MXP USER GUIDE About Local PC Display Using the Display as Local PC Display When using the screen as your PC screen, we recommend that you set Local PC Display to On – see Screen Settings in Control Panel. This implies that you can display your PC locally while having a video-conference, and you can keep on working without having the Far End party viewing your PC screen.
Getting Acquainted with the System Sound Matters TANDBERG 1700 MXP USER GUIDE Mic Off Loudspeakers or Headset? To mute the microphone during a call, press the Mic Off button. An on-screen indicator appears in the upper right corner when the microphone is Off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic Off button one more time will activate the microphone again. Your system comes with built-in loudspeakers and microphones.
Getting Acquainted with the System Numerical Keypad Features TANDBERG 1700 MXP USER GUIDE What Happens When You Press a Key on the Numerical Keypad? Using the Numerical Keypad in Alphanumerical Mode That depends on the context. The following guidelines apply: • • Pressing a Numerical key when outside a call will produce the Call menu. Whenever alphanumerical entries are expected by the system, a small abc appears in the right lower corner of the entry field.
Getting Acquainted with the System Standby TANDBERG 1700 MXP USER GUIDE About Standby The system will automatically go to Standby Mode when it is not in use. In Standby Mode, the screen(s) will turn black. It is, however, still possible to receive incoming calls. To Enable Immediate Standby Mode The Standby Mode of the system should be enabled if the system is to be left idle.
Call Handling We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php Your TANDBERG 1700 MXP can do point-to-point video and telephone calls as well as video conferences with up to 4 video calls and 3 telephone calls (this is called MultiSite). This section of the User Guide outlines the call handling procedures and features.
Call Handling Access Codes TANDBERG 1700 MXP USER GUIDE About Access Codes Making Calls when Prompted for an Access Code Your TANDBERG system may, or may not, be set up to require Access Codes to be typed in before a call can be made. Access Codes are used for two things; call restrictions and billing opportunities. Call restrictions may be applied by installing a file of valid access codes that must be entered to permit calls to be made.
Call Handling Making Point-to-Point Video & Telephone Calls Manually TANDBERG 1700 MXP USER GUIDE Making Video Calls Manually Select Make a Call from the menu, sure Video Call is selected (as shown here). If not, Make see below for details. the dial number manually using the Numerical Enter Keypad. When dialling manually, observe the guidelines given in Numerical Keypad Features. Use * as separator in IP addresses.
Call Handling Making Point-to-Point Calls Using the Phone Book TANDBERG 1700 MXP USER GUIDE About the Phone Book System Asks for Access Code? Using the Phone Book is time saving and prevents you from inadvertently calling the wrong number. The contacts are sorted alphabetically. The contact names are displayed in the list and the telephone or video numbers of the selected contact will be displayed at the bottom line.
Call Handling Making Calls with Two Parties at the Same Time (Non-MultiSite Systems Only) About this Feature Non-MultiSite equipped systems may call another party when already in a call. Thus you may have two calls running at the same time. Note that the two parties will not be able to communicate with each other. The feature requires H.323 or SIP to work. TANDBERG 1700 MXP USER GUIDE Calling Two Parties Simultaneously Assuming you already are in an H.
Call Handling Transfer of a SIP Call (Non-MultiSite Systems Only) About Transfer During a call you may transfer the other party to a third party and disconnect yourself from the call. Call Transfer comes in two flavours; Consultative and Unattended Transfer. TANDBERG 1700 MXP USER GUIDE Consultative Transfer Call two parties at the same time as outlined on the previous page. Both calls must be of SIP type.
Call Handling MultiSite Conferences – Adding Calls TANDBERG 1700 MXP USER GUIDE About MultiSite Conferences Conference systems with built-in MultiSite can handle up to 4 IP video calls and 3 IP telephone calls simultaneously. Adding Calls You may set up a video meeting with many participants in advance and/or you may add participants during a conference. This is called to Add Another Call.
Call Handling Altering the Call Settings About Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the default call settings if the settings are not altered. TANDBERG 1700 MXP USER GUIDE To Alter the Call Settings Select Make a Call from the menu. Set the Call Settings as required. Navigate to Default Call Settings and click OK. In this case the field is labeled Default Call Settings.
Call Handling Streaming About Streaming TANDBERG 1700 MXP USER GUIDE Streaming Settings Streaming lets you broadcast your meeting to participants on the web. The web participants can view the meeting, listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if MultiSite), selfview, far end and Dual Video Streams are accessible via http. Tip! The streaming source setting is not available when streaming only is supported outside a call.
Call Handling Answering an Incoming Call TANDBERG 1700 MXP USER GUIDE About Incoming Calls and Privacy Using Do Not Disturb Incoming Calls will Produce the Below Menu You may want to set up your system so that the microphone is switched off whenever you receive an incoming call. By pressing the Microphone Off key you will prevent callers from hearing you without your control (press again to activate). There is a Do Not Disturb function available on your system.
Call Handling Ending an Ongoing Call TANDBERG 1700 MXP USER GUIDE Ending a Point-to-Point Call Use either of the below methods: • • Press the End Call button ( ) on the remote control. Press the OK/Menu button on the remote control to display the menu. Ending a MultiSite Call Use either of the below methods: • • Presets Press the End Call button ( ) on the remote control. Press the OK/Menu button on the remote control to display the menu.
Call Handling Basic Phone Book Features TANDBERG 1700 MXP USER GUIDE Accessing the Phone Book To access the Phone Book, press the Phone Book button ( ) on the remote control or select the Phone Book icon in the Call menu. The Call Log – Placed, Missed & Received Calls Call Log Options Presets Snapshot Touch tones Accessing the alphanumeric characters Presets Snapshot Touch tones Toggle between ABC and abc mode by pressing the # key.
Call Handling Searching in the Phone Book TANDBERG 1700 MXP USER GUIDE About Searching in the Phone Book The My Contacts may contain up to 200 entries and the entire Phone Book (which may include server based Global Directories) can be virtually unlimited in size. Hence, using the Arrow keys as the only navigation device can easily be a cumbersome experience. What to do? Searching in the Phone Book In the Phone Book use the Cursor keys to move to the Task column and then down to the Search icon.
Call Handling Adding New Contacts to the Phone Book TANDBERG 1700 MXP USER GUIDE Adding a New Contact Manually the Phone Book icon to enter the Press Phone Book. the Arrow keys to navigate down to Use My Contacts OK to produce the contents of My Press Contacts. the Arrow keys to navigate to the Use Add New Contact icon. OK and enter the name of the new Press contact. one line down and enter the Navigate number of the new contact.
Call Handling Editing Entries in the Phone Book TANDBERG 1700 MXP USER GUIDE Editing a Contact in My Contacts the Phone Book icon to enter the Press Phone Book. the Arrow keys to navigate down to Use My Contacts OK to produce the contents of My Press Contacts. the Arrow keys to navigate down to Use the entry to be edited. the Arrow keys to navigate to the Use Task Column and then down to the Edit OK to produce the Edit Contact Press dialogue box.
Call Handling Creating Multisite Contacts in the Phone Book TANDBERG 1700 MXP USER GUIDE About Multisite Contacts* Assume that you frequently use your video system to set up MultiSite video meetings involving the same persons every time. Wouldn’t it be nice to be able to set up the video meeting with just a few clicks? Defining a New MultiSite Contact the Phone Book icon to enter the Press Phone Book. the Arrow keys to navigate to the Use My Contacts and press OK. OK to produce the submenu.
Call Handling Editing Multisite Contacts in the Phone Book TANDBERG 1700 MXP USER GUIDE Viewing the Participants in a MultiSite Contact the Phone Book key to enter the Press Phone Book. the Arrow keys to navigate down to Use My Contacts OK to produce the contents of My Press Contacts. the horizontal Arrow key to expand Use the entry revealing the members. Editing the Participants in a MultiSite Contact the Phone Book and navigate to Enter My Contacts as explained above.
Video Meeting Features We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php Your TANDBERG 1700 MXP can do point-to-point video and telephone calls as well as video conferences with up to 4 video calls and 3 telephone calls (the latter is called MultiSite). Some system features apply to point-to-point calls only, others apply to video conferences only, while a couple of features apply to both situations.
Video Meeting Features Features Overview This section of the User Guide outlines features available during a video call. Main emphasis has been put on features available in point-to-point calls only (as opposed to video conference calls – also called MultiSite calls). However, features available for both point-to-point and MultiSite are also covered.
Video Meeting Features Far End Camera Control – Pan, Tilt and Zoom Panning, Tilting, and Zooming the Far End Camera About Far End Camera Control This is a feature that lets you pan, tilt, and zoom the far end camera. If far end presets* are available you may access these as well, and you may also make use of any video sources that the far end may have at its disposal. TANDBERG 1700 MXP USER GUIDE During a video meeting, press Ok to produce the menu and navigate to the Camera Control icon.
Video Meeting Features Far End Camera Control – Using Far End Camera Presets Using the Far End Preset About Camera Presets The far end may use camera presets to easily vary between predefined camera angles in their own end. Thus they eliminate the need to move their camera about in a manual way. Your 1700MXP may get access to these settings. If no presets have been stored and you try to access far end presets nothing will happen. Navigate to the Display Presets icon. D 13954.
Video Meeting Features Presentation TANDBERG 1700 MXP USER GUIDE About Presentation The Presentation Functionality in the system enables you to show other available video sources in addition to your Main Camera. This is perfect for meetings where you would like to show a PowerPoint presentation, for example. You can even use Arrow keys up and down on the remote control to activate Page Up/Down on the PC (this applies when using VNC only).
Video Meeting Features Dual Video Stream TANDBERG 1700MXP USER GUIDE About Dual Video Stream With Dual Stream (optional) you have the opportunity to show two different live video streams simultaneously, main video and one additional source. This is handy when showing a presentation. You see the live presentation and the live video of the presenter simultaneously. When you start a presentation, Dual Stream starts automatically if both local and remote system supports Dual Stream.
Video Meeting Features Snapshots TANDBERG 1700MXP USER GUIDE About Snapshots The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Video Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. Taking a Snapshot Using the Menu In a call click OK to produce the menu line, if needed, and navigate to the Presentation icon.
Video Meeting Features Gaining Access to the Far End Video Sources TANDBERG 1700 MXP USER GUIDE Far End Video Options About Far End Video Sources In point-to-point video meetings your system may be connected to a system with several inputs for various video sources. You may get access to these by means of the Far End Video controls. As an example let us assume that your system is connected in a point-to-point video call to a large TANDBERG video system with many inputs.
Video Meeting Features Text Chat TANDBERG 1700MXP USER GUIDE About Text Chatting Chatting with the Other Party You may use your 1700MXP to send and receive text messages using the chatting function available. All you need is to select the Text Chat function and use the keypad as you would when sending text messages (SMS) using your cellular phone. In a call click OK to display the menu and navigate to Services. Click OK and navigate to Text Chat.
MultiSite Features We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php The TANDBERG 1700 MXP can handle up to 4 IP video calls and 3 IP telephone calls simultaneously. To be able to do this, the 1700 MXP has a built-in MCU (Multipoint Control Unit) called MultiSite. This feature turns your TANDBERG 1700 MXP into a true video conferencing system.
MultiSite Features Video Meetings with Several Participants – an Overview TANDBERG 1700 MXP USER GUIDE About MCU and MultiSite The TANDBERG 1700 MXP can handle up to 4 IP video calls and 3 IP telephone calls simultaneously. To be able to do this, the 1700 MXP has a built-in MCU (Multipoint Control Unit) called MultiSite. The MultiSite supports both Split Screen and Voice Switched mode – see below.
MultiSite Features Request and Release Floor TANDBERG 1700 MXP USER GUIDE Automatic Full Screen When Requesting Floor About Requesting and Releasing Floor You may set up the system to switch to full screen each time someone requests the floor. This is done in the Control Panel – see Floor to Full Screen in Settings > Video. When requesting floor, your video will be broadcasted as the large picture to all other parties in the conference.
MultiSite Features Assign Floor TANDBERG 1700 MXP USER GUIDE About Assigning Floor Automatic Full Screen When Requesting Floor If your system is the one connected to all the other systems, you will be the host of the meeting and you will be able to assign the floor to others. You may set up the system to switch to full screen each time someone requests the floor. This is done in the Control Panel – see Floor to Full Screen in Settings > Video.
MultiSite Features Terminal Names TANDBERG 1700 MXP USER GUIDE About Terminal Names You may want to see a list of all the participants in a MultiSite video meeting. For this purpose there is a list of the terminal names available. Displaying Terminal Names In a MultiSite call (a video meeting) click OK to display the menu and navigate to Services. D 13954.01 JUNE 2006 Click OK to enter the submenu and navigate to Terminal Names. 54 Click OK to display a list of the meeting participants.
MultiSite Features Layout TANDBERG 1700 MXP USER GUIDE About Layout When you are the host of a MultiSite video meeting, you have control of the main conference image layout. The layout chosen by you is transmitted to the other participants as a single image and its layout cannot be changed by them. However, they may configure their own screen using the Layout button on the Remote Control. Their choices are the image you send out in full screen or as side-by-side: your image and their selfview.
Control Panel We recommend that you check out the TANDBERG web site regularly for updated versions of this manual: http://www.tandberg.net/support/ documentation.php In order to provide you with the expected high level of TANDBERG video conferencing quality, the unit needs to be configured properly. This section explains the details of the Control Panel. Please observe that the Settings may be password protected. A password will then be needed to gain access to the settings described in this section.
Control Panel Settings The Remote Control TANDBERG 1700 MXP USER GUIDE Mic Off turns your microphone on and off. Presentation key switches to a predefined presentation source. If the Presentation key is held down for 1 second then the Presentation video sources menu will appear. Press OK/Menu to show the menu and select menu items. Arrow keys are used to navigate in the menus. Volume + and – adjusts the volume. Use Zoom + and – to zoom the camera in and out.
Control Panel An Overview of the Control Panel Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. The Control Panel will now be displayed. TANDBERG 1700 MXP USER GUIDE Control Panel Options The different parts of the Control Panel are explained on the following pages.
Control Panel An Overview of the Control Panel Settings General Settings TANDBERG 1700 MXP USER GUIDE Presentation Settings Menu Settings Video Settings Call Quality Settings Restore Default Settings Security Settings D 13954.
Control Panel Password Protection of the Control Panel Settings Password Protection All settings of the Control Panel may be password protected by a pin code consisting of up to five digits. Whenever you click the Settings icon in the Control Panel, you will prompted to key in this pin code in order to gain access to the settings. Set a Password Clear an Existing Password Log in the same way as when gaining access to a password protected Control Panel Settings menu.
Control Panel > General Settings General Settings – an Overview Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel. Press OK and use the Arrow keys to move to General. Press OK. TANDBERG 1700 MXP USER GUIDE Language Set the language used in the menus. Choose between English, Deutsch, Français, Italiano, Norsk, Svenska, Español, Português, Pyccкий, Suomi, Chinese, Chinese traditional, Korean, Japanese, and Thai.
Control Panel > General Settings Language TANDBERG 1700 MXP USER GUIDE Language Set the language used in the menus. Choose between English, Deutsch, Français, Italiano, Norsk, Svenska, Español, Português, Pyccкий, Suomi, Chinese, Chinese traditional, Korean, Japanese, and Thai. International Name If the System Name contains Asian and non-standard ASCII character text input (includes even languages like Norwegian, French, Polish etc.
Control Panel > General Settings System Name Settings TANDBERG 1700 MXP USER GUIDE System Name Identifies the system: • • • • • • On the welcome screen of your system During an MCU conference call When using the Web-interface When the codec is acting as an SNMP Agent Towards a DHCP server As H323 ID. If H.323 ID is configured in H.323 settings, it will be used instead of System Name. System Name is blank by default, can be alphanumeric, and up to 50 characters long.
Control Panel > General Settings Autoanswer TANDBERG 1700 MXP USER GUIDE autoanswer The autoanswer setting determines whether an incoming call is put through automatically or manually. On. The system will automatically answer all incoming calls. On+Mic Off. The system will automatically answer all incoming calls and switch the microphone off when the call is connected. Press Mic Off on the Remote Control to switch the microphone back on. Off.
Control Panel > General Settings Phone Book Settings TANDBERG 1700 MXP USER GUIDE Corporate Directory On The Corporate Directory is available in the menu. Off The Corporate Directory is hidden from the menu and is unavailable for users. Camera Presets Snapshot Touch tones IP address Enter the IP address or the DNS name of the Directory Service that provides the Phone Book. CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > General Settings External Services TANDBERG 1700 MXP USER GUIDE External Services On Set this to On when External Services are available. Off Set this to Off when External Services are unavailable. Camera Presets Snapshot Touch tones IP address Enter the IP address or DNS name of the Service Provider Host for External Services. What is External Services? In general, External Services include any HTTP and HTML based contents your Service Provider may offer.
Control Panel > General Settings Permissions TANDBERG 1700 MXP USER GUIDE Access Code An access code will help you control the use of the system. All users must enter a code to identify themselves when making a call and the call may then be charged on their account. Access Codes are handy for group systems where there are more users or divisions that share the costs of using the system. Access Code can be set to On and Off. More on Access codes overleaf.
Control Panel > General Settings > Permissions Access Codes TANDBERG 1700 MXP USER GUIDE About Access Code Applications Defining and Uploading Access Codes Access Codes Activated – How It Looks As an administrator you may set up the system to request codes to be entered before a call can be made. These codes are referred to as Access Codes and can be used to define the types of calls made (internal/external/to an invoicable client etc.).
Control Panel > General Settings Screen Settings TANDBERG 1700 MXP USER GUIDE Picture Layout Picture-in-Picture example Picture-outsidePicture example Picture in Picture (PIP). Pressing the Layout button on the remote will result in an extra picture in smaller view (Picture in Picture). Press the Layout button to move it around in the corners of the screen and finally hide it. Pressing and holding Layout for 1 second will hide the small picture directly from any position.
Control Panel > General Settings Software Options TANDBERG 1700 MXP USER GUIDE The system has a modular design allowing you to add functionality when you need it. This functional expansion requires codes available through your TANDBERG Representative. Camera Presets Snapshot Touch tones The system requires a valid option key to activate MultiSite and/or Presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key.
Control Panel > General Settings Date and Time Settings TANDBERG 1700 MXP USER GUIDE NTP IP This is the NTP time server address from which the system can get updated time information. See IP Services for more details. Auto. The NTP IP address is set automatically. Camera Presets Snapshot Manual. The NTP IP address is set manually. Touch tones IP Address The IP Address or DNS name for obtaining the date and time information. Time Zone Select the correct time zone for the location of your system.
Control Panel > Menu Settings Menu Settings TANDBERG 1700 MXP USER GUIDE Getting to This Menu Press OK to produce the below menu. Number key Mode Set this to ON to enable a pop-up menu letting you choose what to do when pressing a number key – choose between Manual, Add another Call, Dial extension number and Use Presets. When set to Manual you will be prompted to choose what to do. Power users may want to switch this off, which is why this menu item exists.
Control Panel > Menu Settings Kiosk Mode Settings TANDBERG 1700 MXP USER GUIDE Kiosk Mode In Kiosk Mode the system is set to a simplified state where it can be controlled with just the Arrow keys and OK. You will get a simplified on-screen menu with only the basic functionality available to: • • • • Kiosk mode Set to On to activate Kiosk Mode. Observe that deactivation can take place thorugh the system’s web interface, telnet or data port only.
Control Panel > Menu Settings Startup Settings TANDBERG 1700 MXP USER GUIDE Welcome Menu The Welcome Menu contains the Main Menu, System Status, your System Name and dial-in numbers. Set to On to produce the Welcome Menu when the system wakes up from standby mode. Set to Off to disable the Welcome Menu when the system wakes up from standby mode. Press the OK button to open the Welcome Menu.
Control Panel > Menu Settings Icons TANDBERG 1700 MXP USER GUIDE Microphone Off This indicator is shown when the microphone is turned off. Press the Mic off button again to turn the microphone back on. Volume Off This indicator is shown when the volume is turned off. Press Volume + to turn the volume back on. On Air Camera Presets Snapshot When you have the floor in a multisite conference this is indicated by the On Air icon.
Control Panel > Presentation Settings Presentation Settings – an Overview Getting to This Menu Press OK to produce the below menu. TANDBERG 1700 MXP USER GUIDE presentation start Your system has optional Dual Video Stream capabilities, which means that you can show two video streams simultaneously. Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when starting a presentation. Dual Stream requires the Presenter Option and H.
Control Panel > Presentation Settings Presentation Start / H239 Enabling TANDBERG 1700 MXP USER GUIDE presentation start Your system has optional Dual Video Stream capabilities, which means that you can show two video streams simultaneously. Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when starting a presentation. Dual Stream requires the Presenter Option and H.263 video.
Control Panel > Presentation Settings Call Video Source TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Call Video Source The Call Video Source is the default video source you would like to use in a call. If you use Main Camera as Call Video Source, the system will start with Main Camera every time you make a call,regardless of what the previous video source was. Moving up and down in menu.
Control Panel > Presentation Settings Presentation Source TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Presentation Source The Presentation Source is connected to the Presentation button on the Remote Control. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. Moving up and down in menu. Camera Presets Snapshot CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > Presentation Settings Snapshot Source TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones snapshot Source When you take a snapshot, this will be from the Snapshot Source. Current is the default Snapshot Source. This means that you take a snapshot of the video source that is currently active. Moving up and down in menu. Camera Presets Snapshot CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > Presentation Settings Auto-Display Snapshot TANDBERG 1700 MXP USER GUIDE Auto-Display Snapshot Select Auto to automatically display a received snapshot. Set Auto-Display Snapshot to Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Auto-Display Snapshot set to Manual, you must enter the Presentation menu to display a snapshot. Auto.
Control Panel > Presentation Settings PIP Placing TANDBERG 1700 MXP USER GUIDE A Picture in Picture (PIP) is a smaller picture placed in one of the corners of the screen. The PIP enables you to see an extra picture in your video conference. A picture in picture can be nice when you use Dual Video Stream and you need an extra window to see all the pictures. You can, of course, show or hide the PIP with the Layout button on the remote at any time.
Control Panel > Presentation Settings VNC Settings TANDBERG 1700 MXP USER GUIDE VNC Settings VNC Settings is necessary when using a VNC presentation. See PC Soft Presenter and VNC for more information on how to use VNC. Camera Presets Snapshot Touch tones Address The IP-address of the PC with the VNC software installed. To find the IP-address of the PC, place the mouse pointer on the VNC program icon in the lower right corner of the Windows taskbar.
Control Panel > Presentation Settings PC SoftPresenter and VNC TANDBERG 1700 MXP USER GUIDE About PC SoftPresenter Configuring the VNC Server Software: Showing PC Contents Using the PC Soft Presenter & VNC PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software must be installed on the PC. Free software can be downloaded from http://www.
Control Panel > Call Quality Settings Call Quality Settings – an Overview TANDBERG 1700 MXP USER GUIDE Getting to This Menu audio algorithm Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. aac-ld 128 The system will automatically select the best audio algorithm based on the call rate and the capabilities of the remote system.
Control Panel > Call Quality Settings Video Algorithm TANDBERG 1700 MXP USER GUIDE Video algorithm The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues when calling other systems. H.261 Legacy video compression and decompression. The system will always have H.261 enabled. Consequently, there is no way of unchecking H.261. H.
Control Panel > Call Quality Settings Audio Algorithm TANDBERG 1700 MXP USER GUIDE audio algorithm The system will automatically select the best audio algorithm based on the call rate and the capabilities of the remote system. Use this menu to disable audio algorithms in case you want to remove “low quality” audio, or if you have interoperability issues calling other systems. G.711 Normal quality audio (telephone quality 3.1kHz at 64kbps).
Control Panel > Call Quality Settings AAC-LD 128 kbps (Stereo Audio) TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones AAC-LD 128 kbps (Stereo Audio) Specify a call rate for 128 kbps AAC-LD. From this call rate and above, “128 kbps AAC-LD” is available. On lower call rates “64kbps AAC-LD” is available. Moving up and down in menu. Camera Presets Snapshot CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > Call Quality Settings Natural Video TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Natural Video Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Continuous Presence MultiSite calls. Moving up and down in menu. Camera Presets Snapshot Touch tones Auto Natural Video.
Control Panel > Call Quality Settings Maximum Upstream Rate (kbps) TANDBERG 1700 MXP USER GUIDE Max Upstream Rate (kbps) The Max Upstream Rate (kbps) defines your wanted maximum transmitted call rate. In this way you may limit the outgoing bandwidth whilst keeping the maximum incoming bandwidth – a feature quite useful for home office applications with different upstream and downstream rates, typically ADSL. CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > Call Quality Settings Video Quality TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Video Quality Different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default. Auto. The system chooses the best of Motion or Sharpness depending on picture layout and bandwidth. Sharpness. Optimized for sharp video (4CIF/4SIF, SVGA, XGA, w720p).
Control Panel > Call Quality Settings > Video Quality About Intelligent Video Management (IVM) on TANDBERG Systems TANDBERG 1700 MXP USER GUIDE Intelligent Video Management (IVM) IVM Resolution Native Resolutions You may configure the picture sent from your TANDBERG system depending upon specific requirements and applications adding an additional level of flexibility and adaptability.
Control Panel > Call Quality Settings Default Call Settings – an Overview TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Default Call Settings are connected with Call Settings in the Call Menu. If you leave Call Settings unchanged when making a call, the system will use the Default Call Settings in the call. In addition to the Call Type, Net, and Bandwidth, you also find settings for H.320 Auto bandwidth and H.323 Auto bandwidth in Default Call Settings.
Control Panel > Call Quality Settings > Default Call Settings Default Video Call Settings TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Call Type Call Type can be set to: • • Video Call Telephone Call For MultiSite calls, Call Type enables you to specify both telephone calls and video calls in the same conference. CANCEL Select this icon and press OK to leave the menu undoing any changes. RESTORE DEFAULTS Select this icon and press OK to restore the default settings.
Control Panel > Call Quality Settings > Default Call Settings Default Net Settings TANDBERG 1700 MXP USER GUIDE Network The Network alternatives are: • • • Camera Presets Snapshot Auto H.323 SIP If Auto is selected, the system will select the right network depending on the entered number: Touch tones • If an IP-address (e.g. 10.12.34.56 ) is entered, H.323 is selected. • If the first digits in the number match those set in H.323 Prefix, H.323 is selected.
Control Panel > Call Quality Settings > Default Call Settings Default Bandwidth Settings TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot Touch tones Bandwidth Determines the quality of the video picture. When set to Auto the system will establish a connection using a proper bandwidth for the call, typically 384 kbps for IP calls. When set to Max the system will set up the call with maximum bandwidth depending on the selected network.
Control Panel > Audio Settings Audio Settings – an Overview TANDBERG 1700 MXP USER GUIDE Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. Level Settings Lets you set the maximum levels, which later can be adjusted using the volume control. Alert Tones and Volume Lets you choose among the alert tones available and set the volume. Use the Arrow keys to move to Audio Settings, if applicable. Press OK.
Control Panel > Audio Settings Level Settings Level Settings lets you set each max level independently. The volume control (on the remote control) acts as an attenuator with which you then may adjust the volume without the risk of causing damage to the transducers. Note! When you use the volume control, it may look like you are able set the volume higher than the level specified here (gain, and not just attenuation).
Control Panel > Audio Settings Alert Tones & Volumes TANDBERG 1700 MXP USER GUIDE To make it easy to distinguish between incoming video calls and ordinary telephone calls, we recommend the use of different ringing tones for video and telephone calls. Moving up and down in menu. Camera Presets Snapshot Touch tones Use the vertical Arrow keys to move up and down in the Alert tone list. Press OK to listen to the alert tone selected.
Control Panel > Audio Settings Graphical View of Settings TANDBERG 1700 MXP USER GUIDE Ever wondered how things are connected in your system? The Graphical View is a matrix showing what is connected to what, and by playing test tones you will be able to verify that the connections actually are as you would like them to be. Moving up and down in menu.
Control Panel > Video Settings Video Settings – an Overview TANDBERG 1700 MXP USER GUIDE Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. MCU Status line MultiSite / MCU / DuoVideo indicators can be displayed whenever applicable, not displayed at all, or displayed for a short time. These indicators provide information about the conference.
Control Panel > Video Settings MCU Status Line TANDBERG 1700 MXP USER GUIDE mcu status line Off. The MultiSite / MCU / DuoVideo indicators will not be displayed. On. The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference. Auto. The MultiSite / MCU / DuoVideo indicators will be displayed for a few seconds and then timed out. When grabbing the remote control, the indicators will be shown again.
Control Panel > Video Settings Floor to Full Screen TANDBERG 1700 MXP USER GUIDE floor to full screen When Floor to Full Screen is enabled, someone who requests floor will be seen by all participants as full screen. When Floor to Full Screen is Off, someone who request floor in a MultiSite conference using the 5+1 layout will be seen in the large square, rather than full screen. Off. The participant who has the floor is displayed in the MultiSite layout that is used. On.
Control Panel > Video Settings Web Snapshot TANDBERG 1700 MXP USER GUIDE web snapshot The system is able to generate JPEG snapshots and provide them when requested (as ‘http get’ or via ftp). Note that web snapshots are not generated if the conference is encrypted. Off. Snapshots generation is disabled. On. Snapshots generation is enabled. Using the file system It is possible to access a file system within the TANDBERG system by means of ftp.
Control Panel > Video Settings MultiSite Picture Mode TANDBERG 1700 MXP USER GUIDE Multisite picture mode MultiSite Picture Mode determines the default layout of a MultiSite call. Available layouts are: • • • • Auto Split 4 Split 5+1 Split Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Camera Presets Snapshot Auto Split displays all participants on the screen simultaneously.
Control Panel > Video Settings Video Name TANDBERG 1700 MXP USER GUIDE Camera Presets Video Name Snapshot Touch tones As a default, the video inputs are given the names Main Cam, PC, Doc Cam, VCR, AUX or VNC, dependent on what video sources are available on your system. You may change these to your liking. Note, however, that the video names cannot exceed eight characters.
Control Panel > Security Settings Security Settings – an Overview TANDBERG 1700 MXP USER GUIDE Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. Encryption Provided that all parties participating have equipment supporting encryption, video meetings may be set up using encrypted communication. Encryption mode Lets you choose between AES, DES, or have the system itself find the mode that all parties support.
Control Panel > Security Settings Encryption TANDBERG 1700 MXP USER GUIDE Encryption (Country specific) Off. The system will not send or receive encrypted data. On. The system will only send and receive encrypted data. The call will not be established if not all participants support encryption. Auto. The system will try to set up calls using encryption. • Point to point calls: If the far end system supports encryption (AES or DES), the call will be encrypted.
Control Panel > Network Settings Network Settings – an Overview TANDBERG 1700 MXP USER GUIDE Getting to This Menu Press OK to produce the below menu. lan settings The LAN settings contain: • • • • • • • • Use the Arrow keys to move to the Control Panel and press OK. IP Settings H.323 Settings SIP Settings Wireless LAN Settings SNMP Settings IP Services Quality of Service 802.1X Settings. Network Profiles This menu consists of 7 network profiles; a prefix can be added for each profile.
Control Panel > Network Settings > LAN Settings IP Settings (I) TANDBERG 1700 MXP USER GUIDE IP Settings Remember to restart the system after making changes to IP Settings. Click on the Save & Restart button to do this. Changes in IP Settings menu will have no effect until the system is restarted. IP Protocol IPv4. IP version 4 supported. IPv6. IP version 6 supported. IP Address, IP Subnet Mask, and Gateway will be disabled. Both. Both IP version 4 and IP version 6 supported.
Control Panel > Network Settings > LAN Settings IP Settings (II) TANDBERG 1700 MXP USER GUIDE Ethernet Speed Auto. The codec will auto-detect the speed/duplex on the LAN. 10/Half. The codec will connect to the LAN using 10Mbps speed / Half Duplex. 10/Full. 10 Mbps speed / Full Duplex. 100/Half. 100 Mbps speed / Half Duplex. 100/Full. 100 Mbps speed / Full Duplex.
Control Panel > Network Settings > LAN Settings H.323 Settings (I) TANDBERG 1700 MXP USER GUIDE E.164 alias This is the E.164 address of the system. The E.164 address is equivalent to a telephone number, sometimes combined with access codes. Valid characters are 0–9, * and #. When using a gatekeeper, the system will send a message to the gatekeeper containing both the E.164 address and the H.323 ID of the system. Camera Presets Camera Presets Snapshot Touch tones H.
Control Panel > Network Settings > LAN Settings H.323 Settings (II) – Gatekeeper Settings TANDBERG 1700 MXP USER GUIDE Gatekeeper Discovery Auto. The system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the gatekeeper as well. If no gatekeeper responds, the system will not use a gatekeeper for making H.
Control Panel > Network Settings > LAN Settings H.323 Settings (III) – CallManager Settings TANDBERG 1700 MXP USER GUIDE Camera Presets Camera Presets Snapshot Snapshot Touch tones Touch tones CallManager IP The rest of the lower part of the menu is explained on the following pages. Camera Presets Snapshot CANCEL Select this icon and press OK to leave the menu undoing any changes. RESTORE DEFAULTS Select this icon and press OK to restore the default settings.
Control Panel > Network Settings > LAN Settings H.323 Settings (IV) – Advanced NAT Settings TANDBERG 1700 MXP USER GUIDE NAT On. The system will signal the configured “NAT Address” in place of its own IP-address within Q.931 and H.245. Auto. The system will try to determine if the “NAT Address” or the real IP-address should be used within signalling. This is done to make it possible to place calls to endpoints on the LAN as well as endpoints on the WAN.
Control Panel > Network Settings > LAN Settings SIP Settings (I) TANDBERG 1700 MXP USER GUIDE Mode On. Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls. Off. Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Address (URI) is usually a full name or system name.
Control Panel > Network Settings > LAN Settings SIP Settings (II) TANDBERG 1700 MXP USER GUIDE Current RFC’s and Drafts supported: RFC 1889 RTP: A Transport Protocol for Real-Time Applications RFC 2327 SDP: Session Description Protocol RFC 2396 Uniform Resource Identifiers (URI): Generic Syntax RFC 2617 Digest Authentication RFC 2782 DNS RR for specifying the location of services (DNS SRV) RFC 2976 The SIP INFO Method RFC 3261 SIP: Session Initiation Protocol RFC 3262 Reliability of Provisional Responses
Control Panel > Network Settings > LAN Settings Wireless LAN Settings TANDBERG 1700 MXP USER GUIDE SSID (Service Set Identification) Example “WLANNETWORK”. Defines a local network id for this wireless region. It must be the same for all end points and the access point. An endpoint will find the access point if the SSID is correct, however if the encryption key is faulty it will not transmit any data. Community (optional) Community can be used when connecting to an access point where the SSID is the same.
Control Panel > Network Settings > LAN Settings SNMP Settings TANDBERG 1700 MXP USER GUIDE SNMP Trap Host Identifies the IP-address of the SNMP manager. SNMP (Simple Network Management Protocol, SNMP Ver 1) is used to monitor and configure different entities in a network. The system’s SNMP Agent responds to requests from SNMP Managers (a PC program etc.). SNMP traps are generated by the agent to inform the manager about important events.
Control Panel > Network Settings > LAN Settings IP Services TANDBERG 1700 MXP USER GUIDE Camera Presets NTP IP Camera Presets Snapshot Snapshot This is the NTP time server address from which the system can get updated time information. This is a requirement for proper operation if H.235 authentication is implemented. Touch tones Touch tones The Network Time Protocol (NTP) is used to synchronize the time of the system to a reference time server.
Control Panel > Network Settings > LAN Settings Quality of Service (I) – QoS Type TANDBERG 1700 MXP USER GUIDE Camera Presets Camera Presets Snapshot Snapshot Touch tones Touch tones QoS Type IP Precedence. IP Precedence QoS method is used. Please see the following pages for details. Diffserv. Diffserv QoS method is used. Please see the following pages for details. Off. No QoS is used. CANCEL Select this icon and press OK to leave the menu undoing any changes.
Control Panel > Network Settings > LAN Settings Quality of Service (II) – IP Presedence Video TANDBERG 1700 MXP USER GUIDE Camera Presets Camera Presets Snapshot Snapshot IP Precedence Video Touch tones Touch tones Used to define which priority audio, video, data and signalling should have in the network. The higher the number, the higher the priority. The priority ranges from 0 (off) to 7 for each type of packets.
Control Panel > Network Settings > LAN Settings Quality of Service (III) – IP Presedence Telephony TANDBERG 1700 MXP USER GUIDE IP Precedence Telephony Used to define which priority audio should have in the network for telephone calls. The higher the number, the higher the priority. The priority ranges from 0 (off) to 7 for each type of packets.
Control Panel > Network Settings > LAN Settings Quality of Service (IV) – Diffserv Video TANDBERG 1700 MXP USER GUIDE Diffserv Video Used to define which priority Audio, Video, Data and Signaling packets should have in an IP network. The priority ranges from 0 to 63 for each type of packets. Recommended value for video is DiffServ Code Point (DSCP) AF41, which equals the value 34.
Control Panel > Network Settings > LAN Settings Quality of Service (V) – Diffserv Telephony TANDBERG 1700 MXP USER GUIDE Diffserv telephony Used to define which priority Audio packets should have in an IP network for telephone calls. The priority ranges from 0 to 63 for each type of packets. Recommended value for telephony is DiffServ Code Point (DSCP) EF, which equals the value 46.
Control Panel > Network Settings > LAN Settings IEEE802.1x TANDBERG 1700 MXP USER GUIDE Mode The system may be connected to an IEEE 802.1x LAN network. Supported 802.1x protocols are EAP-MD5, EAP-PEAP and EAP-TTLS. The 802.1x authentication are enabled by setting 802.1x Mode to On. On. 802.1x authentication enabled Off. 802.1x authentication disabled Anonymous Identity The 802.
Control Panel > Network Settings > Network Profiles Network Profiles TANDBERG 1700 MXP USER GUIDE Camera Presets Snapshot This menu consists of 6 network profiles (No. 2 is not in use); a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialled. Touch tones The three lower profiles. Using the profiles Nos. 5, 6, and 7 you can enter the name of a profile, prefix and network selection.
Control Panel > Network Settings > Data Port Data Port TANDBERG 1700 MXP USER GUIDE Data Port Camera Presets Snapshot Touch tones The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC, the connecting cable must be a straight through RS232 cable. Set Baud Rate, Parity, Databits, and Stopbits as required for your application.
Control Panel > Restore Default Settings Restore Default Settings (I) TANDBERG 1700 MXP USER GUIDE RESTORING DEFAULT SETTINGS The Default Settings Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel and press OK. Use the Arrow keys to move to Restore Default Settings, if applicable. Press OK. Whilst the Restore Defaults icon is highlighted press OK to restore the default setting. You will be prompted to confirm your intentions.
Control Panel > Restore Default Settings Restore Default Settings (II) TANDBERG 1700 MXP USER GUIDE NetProfile 5 Name: “” HTTPS Mode: Off Video Inputs Source 1 Name: “Main Cam” Conference G722.
Control Panel > Restore Default Settings Restore Default Settings (III) TANDBERG 1700 MXP USER GUIDE AutoAnswer Delay: 10 Streaming Hops: 1 StrictPassword: On Kiosk Menu: On AutoPIP Mode: On Streaming Address: “224.2.201.
Control Panel On-line User Guide Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel.and press OK. The Control Panel will now be displayed TANDBERG 1700 MXP USER GUIDE The On-line User Guide serves to help you when you feel stuck and time is short. It is not an exhaustive presentation of the system’s features, but it comes in handy whenever you need to get yourself up and going. Page number / total number of pages for this topic.
Control Panel Diagnostics – an Overview Getting to This Menu Press OK to produce the below menu. Use the Arrow keys to move to the Control Panel.and press OK. The Control Panel will now be displayed TANDBERG 1700 MXP USER GUIDE The Diagnostics allows testing of individual system components and displays the current system settings. System Information Select System Information to view system numbers, line status, software version, hardware serial number and other useful information.
Control Panel > Diagnostics System Information TANDBERG 1700 MXP USER GUIDE System Information Select System Information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the System Information list. Camera Presets Snapshot System Information is a two-page display providing system information. Cancel View Adminstrator Settings Detailed Call Status Call Status System Information D 13954.
Control Panel > Diagnostics Call Status TANDBERG 1700 MXP USER GUIDE Call Status Comprehensive information about the call is available through the Call Status window. The menu has two columns, one for transmitted and one for received audio/ video/data information. If Dual Stream or MultiSite is available on your system and in use, pressing the UP/DOWN keys will show one page per connected site. Cancel View Adminstrator Settings Detailed Call Status Call Status On-line User Guide D 13954.
Control Panel > Diagnostics Detailed Call Status TANDBERG 1700 MXP USER GUIDE Detailed call status The detailed call status menu provides detailed information on packet loss and jitter. Cancel View Adminstrator Settings Detailed Call Status Call Status On-line User Guide D 13954.
Control Panel > Diagnostics System Selftest TANDBERG 1700 MXP USER GUIDE System Selftest The system performs a check to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active. D 13954.
Control Panel > Diagnostics View Adminstrator Settings TANDBERG 1700 MXP USER GUIDE Adminstrator settings This window displays all the system settings. Use the Arrow keys on the remote control to scroll through the list. Camera Presets Snapshot • • • D 13954.
Control Panel > Diagnostics IP Address Conflict Check TANDBERG 1700 MXP USER GUIDE IP address conflict check The system will give a warning if there is an IP conflict. Initiate this check by selecting IP Address Conflict Check. D 13954.
Control Panel > Diagnostics Warnings TANDBERG 1700 MXP USER GUIDE Warnings Any warnings registered by the system will be displayed in the Warnings menu. Open a warning in the list to get more information about the warning. D 13954.
Control Panel Audio Demo TANDBERG 1700 MXP USER GUIDE Audio demo A feature designed to demonstrate the high quality of the TANDBERG audio system. Click on the Audio Demo button to demonstrate the high quality of the TANDBERG audio system. D 13954.