Select this option if you want the MCU to inform
the gatekeeper about its availability or non-
availability. This information will be used by the
gatekeeper when it is selecting where to place ad
hoc conferences.
Only use this option where multiple MCUs are
registered with the same MCU service prefix on
the same gatekeeper.
If you select this option, you must configure the
thresholds for conferences and/or video ports.
Thresholds:
: Enter any number of
conferences between 0 and 200. (A
value of 0 will mean that the MCU will
always indicate 'unavailable'.)
: Enter a number between 0
and the number of video ports on your
MCU; for example, on an MCU 4205,
there are 12 video ports, so enter a
number between 0 and 12. (A value of 0
will mean that the MCU will always
indicate 'unavailable'.)