Specifications

78 Appendixes.
A.5. Drop
Drop test
Standard ASTM D-4169
Drop sequence 10 drops, 1 corner, 3 edges, 6 faces
Drop height 76 cm (30 inches)
Table A.6. StorageLoader drop test.
A.6. Climatic Specifications
Temperature
Operating Range
+10°C to +35°C
Gradient
10°C/hour
Non-Operating Range
-35°C to +60°C
Gradient
20°C/hour
Table A.7. StorageLoader temperature specification.
Installing the equipment in a closed or multi-unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient.
Humidity
Operating Range 20%Rh to 80%Rh
Gradient 10%Rh/hour
Non-Operating Range 10%Rh to 90%Rh
Gradient 20%Rh /hour
Table A.8. StorageLoader humidity specification.
Altitude
Operating Range 150 to 3050 m (500 to 10000 ft)
Non-Operating
Range 150 to 3050 m (500 to 40000 ft)
Table A.9. StorageLoader altitude specification.