User manual

Tandberg Data
Spares/Accessories
90
StorageLoader Installation and User Manual
A.4
Mechanical Shock Specifications
Mechanical Bump/Shock
Axes
X, Y, Z
Directions
Positive and negative
Pulse
interval
3 seconds
Pulse
shape
Pulse
duration
Pulse
Level
Pulses/axis/direction
Operating
Half sine
5ms
3g
1000
Storage
(X,Z)
Half sine
8ms
20g
3
Storage (Y)
Half sine
8ms
15g
3
Table A
- 5
StorageLoader mechanical shock levels
A.5
Drop
Drop tes
t
Standard
ASTM D
-
4169
Drop sequence
10 drops, 1 corner, 3 edges, 6 faces
Drop height
30 inches
Table A
- 6
StorageLoader drop test
A.6
Climatic Specifications
Temperature
Operating
Range
+10
C to +35
C
Gradient
10
C/hour
N
on
-
Operating
Range
-
35
C to +60
C
Gradient
20
C/hour
Table A
- 7
StorageLoader temperature specification
Installing the equipment in a closed or multi
-
unit rack assembly,
the operating ambient temperature of the rack environ
ment may
be greater than room ambient.
Humidity
Operating
Range
20%Rh to 80%Rh
Gradient
10%Rh/hour
Non
-
Operating
Range
10%Rh to 90%Rh
Gradient
20%Rh /hour