User manual

Tandberg Data
Maintenance
StorageLoader Installation and User Manual
83
1209
Failed to fetch at
slot 09
Failed to eject
cartridge from
drive
1. Reboot the loader and retry the
operation.
2. Try
to eject the cartridge from
the drive via the front panel menu.
3.Remove the drive FRU. Connect
power to drive and push the
drive’s eject button. If this fails,
remove cartidge by following the
drive’s emergency eject
procedure.
Defect drive or
robotics. D
efect
cartridge.
2000
Drive not found
Communication
error between
the loader and
the drive.
1. Reboot the loader and retry the
operation.
2. Remove back
-
panel cover plate
and check the SCSI cabling and
the ADI cabling.
SCSI and signal
cables, power
cable
s; defective
power supply;
defective drive.
2001
Drive hardware
fault detected.
The drive has
reported a
hardware fault.
Reboot the loader and retry the
operation. If the problem persists
replace the drive.
Defective drive