User manual

Tandberg Data
Maintenance
80
StorageLoader Installation and User Manual
Forgot password on FPI
• Look up the RMI IP address from the front panel menu
(view data menu).
• Connect the RMI interface and perform a memory dump of
the loader (see user
and installation guide for details).
• Send the memdump to your Service representative. The
FPI password can be decoded from the memdump by using
a special SW.
7.7
The Error Screen
When the
StorageLoader
detects an
error condition, the
red/amber
Fault
LED is illuminated and one of the error screens appears on the
front panel. Figure 7.1 illustrates how the
StorageLoader
reports
error conditions on the front panel display:
Error : 1109
6A0133
Failed to stow
at slot 9 (Drive)
Details
Acti
ons
Figure 7.1 Error Code Page
The top line shows an Error code in the following format: XXXX
-
YYRRVV
The XXXX is the error number, while the YY is the internal loader
error code. The RRVV is the FW revision numbers, where RR is the
major revision and VV
is the minor revision.
The next two lines give more detailed error information. There are
two option buttons, “Details” and “Actions”. Pressing the Details
button gives access to a multi
-
page error description text. Pressing
Action gives access to a set of
actions that can be taken to recover
from the error. An example of pressing “Details” and continuing with
pressing “More” is shown in figures 7.2 and 7.3.
Reboot the Loader
and retry the
operation.
More
Back