User manual

Tandberg Data
Maintenance
58
StorageLoader Installation and User Manual
flashes in addition to the Amber LED
being lit. The program ming operation
takes less
than one minute.
9. When reprogram ming is completed, the
loader will do a normal reboot
If the firmware upgrade operation failes during point 8 due to a
power shut
-
down or similar, the loader may require service.
To verify that the FW version in the loader is correct, enter the
view data menu. Select the Autoloader Info and from there the
“Loader Firmware Revision” e
ntry to see the revision number.
6.2.2
Possible Upgrade Problems
If a power loss or a failure occurs during code download and ECC
Checking, the original FW may be intact. I t is possible to restart
the FW upgrade procedure. However, if the failure occurs during
flash erase or program ming, the firmware will be corrupted and a
special procedure must be used to load a new code. Contact your
Technic
al Support Representative for assistance.
6.3
Embedded Diagnostics
The StorageLoader includes two levels of diagnostics:
The Power
-
On Self Test (POST
)
Performs several
verification and memory tests when you power on th
e unit.
User Diagnostics
Selectable from the front panel
6.4
Reinstalling the Transport Lock
Before the
StorageLoader is
shipped over a distance,
the transport lock must
be installed. The
transport lock will
prevent damage to the
rob
otics during transport
and handling.
Note:
Damage to the
robotics during shipping
will not be covered by
warranty
unless the
transport lock is
Figure
6.1
Transport lock marked with
red plastic tab