User manual

Tandberg Data
Maintenance
52
StorageLoader Installation and User Manual
Figure 5.3 Remote Management Status Page
The figure provides an updated status of drives, robotics an
d
cartridges using color
-
coding and symbols.
The Drive and Robot status will be shown as a green (OK), yellow
(Warning) or red (Error) dot. I f you click on the text, additional
information will be shown in a pop up window.
The cartridge locations are shown with rectangles in the slots or
the drive.
The status codes are:
Black
Empty slot, no cartridge present
Grey
Cartridge present
Blue
Cleaning cartridge in the slot
Yellow
Warning
Red
Error