Step 3. Connecting Power Cable
The StorageLoader is offered both w
ith AC and DC connection.
-
DC connection.
This version is offered with special connector and -
48 VDC volt
age
.
This is described in appendix. A2. Please note grounding
requirements
and special connector
.
AC connection
Before connecting the StorageLoader to your host com puter
system you should run the self-diagnostic of the unit. This
preparation requires power to the StorageLoader. Go through the
following steps to perform this test:
1.
Use the power cables from the accessories included in the
shipment. Make sure you select the power cord suited for
your power system.
2.
Plug the power cable into the rear of the StorageLoader (see
figure 3.8). Plug the other end of the cable into a properly
grounded electrical outlet.
Note
:
Reliable earthing depends on earthing in the AC electrical
outlet, in which the StorageLoaders power cable is connected.
Adding the StorageLoader to an existing rack installation can cause
a leaking current fault condition because of the summ ation of the
leaking currents. For security, a 250V 2A (H) fuse is located near
the power switch.
3.
Turn on the StorageLoader
by switching the Power
Switch to 1.
If the transport lock is
present the loader will
detect this and instruct
the user to rem ove it, see
next step.
Figure 3.8
Main
Power switch,
fuse
holder and power cord connection