User manual
Tandberg Data
Operation and Configuration
StorageLoader Installation and User Manual
17
StorageLoader 1U uses 1U of
vertical rack space. The rails
must be installed in a full U
position (The bottom of the
rails must be aligned with the
bottom of a U), see figure 3.2.
Figure 3.2 Rack m
ount rail
Installing the “Rail Left Assembly”
1.
Measure the length between the rear rack mount rails and
the front rack mount rails. If the m easurem ent is shorter
than the StorageLoader, move the two sets of screws
M4x12, washers and nuts shown in Figure 3.
3.
2.
Adjust the “Rail Left Assembly” to fit the measurem ent in
step 1.
3.
Use a 7 mm open
-
end wrench together with the screwdriver
to tighten the two M4x12 screws to fix the rail length.
Note
:
Using more than two screws will increase the stability
of the Rack M
ounting Kit.
4.
Place the “Rail Left Assembly” on the left side of the rack,
between the rear rack m ount rail and the front rack mount
rail.
5.
Mount the “Rail Left Assem bly” at desired height using one
M6x12 screw in front (upper hole in rail only) and two M6x1
2
screws at the backside.
See figure 3.4.
Installing the “Rail Right Assembly”
Follow the instruction for left side only using the “Rail Right
Assembly” on the right side of the rack.