StorageLoader Installation and User Manual
any activity is always visi
ble on the display.
LED Indicators
The two LED indicators are green and amber. They indicate the
StorageLoader activity as follows:
Green LED on: The StorageLoader is either running or ready
for operation.
Green LED blinking: Short blinks followed by long intervals
indicate that the loader is in low power standby mode.
Am ber LED on: Fault LED, the StorageLoader has
encountered an electrical or mechanical failure.
Both LED’s off: The StorageLoader is offline. This is the case
while the loader is initializing, after power-on, and when a
magazine is removed.
Standby Switch
A switch on the front panel provides a Loader Standby. I f the
switch is pushed when the loader is active, the loader will complete
the current operation and go off line and enter standby mode, see
more details in chapter
4.9
,
Standby Functionality
.
Magazine Front Bezel
The front bezel of the magazines is visible from the front.
All
magazine handling is described in detail in chapter
4.8
,
Magazine
Handling
.