User's Manual
- 59 -
Error code Cause Recovery Procedure
DRV Err 1
There has been detection of the drive
exceeding the recommended operation
temperature.
Improve the enviroment temperature.See Appendix
A
DRV Err 2
There has been detection of the drive
input voltage reaching the limit of or
exceeding the permissible range.
Contact your nearest Customer Support Center.
DRV Err 3
A drive firmware error has occurred.
DRV Err 4
A fault has occurred in the drive
firmware or hardware.
DRV Err 5
A fault has occurred in the drive
hardware.
Contact your nearest Customer Support Center.
DRV Err 6
A drive hardware or a media error has
occurred.
Replace the cartridge.
DRV Err 7
A fault of the media has occurred. Replace the cartridge.
DRV Err 8
An error has occurred in the drive
hardware or SCSI bus.
DRV Err 9
An error has occurred in the drive
hardware or RS-422 connection.
DRV Err A
An error has occurred in the drive
hardware.
Contact your nearest Customer Support Center.
COMM.ERROR
The Autoloader detected
communication error with the drive.
・Switch off the power of the Autoloader and then
switch the power back on.
・If the phenomenon has a relapse,contact your
nearest Customer Support Center.
REQ CLNROL
The Autoloader is requesting the
cleaning of the Roller.
・Execute cleaning of the Roller.See”Section 5.1.2”
FATEL ERR.
The door has been forced open during
the transporter operation and the
magazine has been removed.
・Switch off the power of the Autoloader and then
switch the power back on.
MOVE ERROR
The Autoloader detected transporter
error during Load or Unload cartridge.
・Execute cleaning of the Roller.See”Section 5.1.2”
・If the phenomenon has a relapse,contact your
nearest Customer Support Center.
SCSI P Err
The Autoloader detected SCSI parity
error.
・Check the conection of SCSI cable and SCSI
terminator.