User manual
Table Of Contents
- 1. About This Manual
- 2. General Information
- 3. Installation
- 3.1 Performing the Installation
- Step 1. Unpacking the StorageLoader
- Step 2. Installing the StorageLoader in a Rack
- Installing the Rack Mounting Kit
- Installing the “Rail Left Assembly”
- Installing the “Rail Right Assembly”
- Mounting the StorageLoader to the Rack
- How to dismount the StorageLoader from the rack
- Step 3. Connecting Power Cable
- Step 4. Removing the Transport Lock
- Step 5. Running Power-On Selftest
- Step 6. Setting the SCSI Address
- Step 7. Connecting the SCSI Bus Cable
- Step 8. Connecting the Ethernet Connector
- Step 9. Restarting Your System
- Step 10. BCR: Labelling of cartridges
- Step 1. Unpacking the StorageLoader
- 3.1 Performing the Installation
- 4. Operation and Configuration
- 1.
- 5. Remote Management
- 6. Maintenance
- 7. Troubleshooting
- Appendix A – Specifications
- Appendix B – Spare parts/Accessories
- Appendix C – Field Replacement Units (FRUs)

Tandberg Data Spares/Accessories
After replacing a fan, pack the defective fan in the same box you received the
replacement fan, and return it to your support center.
C.4. FRU Power Supply
This FRU consists of the following parts:
S808696 Power Supply FRU StorageLoader 1U
Item Description
Qty
1 Power supply 1
2 Quick Installation Guide Fan 1
Figure C.5 Exchanging a defective power supply
Figure C.6 Removing the fixing screw
To exchange a defective power-supply switch off the loader and
disconnect the power cord. Dismounting the backpanel cover plate by
removin
g
these two screws:
Removing the fixing screw
Remove the fixing screw (see figure aboveError! Reference source not
found.). Withdraw the power-supply and carefully unhook the connectors for
power and fan (see figure belowError! Reference source not found.) before
completely removing the power-supply module.
72 StorageLoader Installation and User Manual