User manual
Table Of Contents
- 1. About This Manual
- 2. General Information
- 3. Installation
- 3.1 Performing the Installation
- Step 1. Unpacking the StorageLoader
- Step 2. Installing the StorageLoader in a Rack
- Installing the Rack Mounting Kit
- Installing the “Rail Left Assembly”
- Installing the “Rail Right Assembly”
- Mounting the StorageLoader to the Rack
- How to dismount the StorageLoader from the rack
- Step 3. Connecting Power Cable
- Step 4. Removing the Transport Lock
- Step 5. Running Power-On Selftest
- Step 6. Setting the SCSI Address
- Step 7. Connecting the SCSI Bus Cable
- Step 8. Connecting the Ethernet Connector
- Step 9. Restarting Your System
- Step 10. BCR: Labelling of cartridges
- Step 1. Unpacking the StorageLoader
- 3.1 Performing the Installation
- 4. Operation and Configuration
- 1.
- 5. Remote Management
- 6. Maintenance
- 7. Troubleshooting
- Appendix A – Specifications
- Appendix B – Spare parts/Accessories
- Appendix C – Field Replacement Units (FRUs)

Tandberg Data Maintenance
Item Description Qty
1 Fan 1
2 Quick Installation Guide Fan 1
To remove the fan, switch off the loader
and remove the power cord. Remove these
two screws and remove the back-
p
anel
Figure C.2 Removing the back panel cover plate
Figure C.3 Removing the fan
Remove the fan fixing screws (see figure aboveError! Reference source not
found.). Unhook the power connector of the fan and carefully replace it. When re-
inserting the fan take care to have the cable in the notch in the chassis. If the cable is
not fully inside the notch it can easily be damaged and cause a new faulty fan.
Fasten the fan fixing screws.
Cable notch in chassis
Fan power cable
Remove the four fan fixing
Figure C.4 Notch in chassis for fan cable
StorageLoader Installation and User Manual 71