User manual
Table Of Contents
- 1. About This Manual
- 2. General Information
- 3. Installation
- 3.1 Performing the Installation
- Step 1. Unpacking the StorageLoader
- Step 2. Installing the StorageLoader in a Rack
- Installing the Rack Mounting Kit
- Installing the “Rail Left Assembly”
- Installing the “Rail Right Assembly”
- Mounting the StorageLoader to the Rack
- How to dismount the StorageLoader from the rack
- Step 3. Connecting Power Cable
- Step 4. Removing the Transport Lock
- Step 5. Running Power-On Selftest
- Step 6. Setting the SCSI Address
- Step 7. Connecting the SCSI Bus Cable
- Step 8. Connecting the Ethernet Connector
- Step 9. Restarting Your System
- Step 10. BCR: Labelling of cartridges
- Step 1. Unpacking the StorageLoader
- 3.1 Performing the Installation
- 4. Operation and Configuration
- 1.
- 5. Remote Management
- 6. Maintenance
- 7. Troubleshooting
- Appendix A – Specifications
- Appendix B – Spare parts/Accessories
- Appendix C – Field Replacement Units (FRUs)

Tandberg Data Maintenance
A.3 Vibration Specifications
A.4
Sinusoidal sweep
Sweep Rates 1 octave/minute
Axes X, Y and Z
Duration 2 hours
Frequency Range (Hz) Level
5 24.2 0.01 in p-p Operating
24.2 500 0.3g
5 27.1 0.02 in p-p Non-Operating (Storage)
27.1 500 0.75g
Transport 5 200 0.5g
Table A - 3 StorageLoader sine sweep levels
Random
Crest factor 3
Axes X, Y, Z
Duration
30 min/axis
Level (g
2
/Hz) Frequency (Hz)
5 2.0E-5
17 3.0E-4
150 3.0E-4
200 8.0E-5
500 8.0E-5
Operating
Total
0.27g
rms
5 2.3E-3
500 2.3E-3
Non Operating/Storage
Total
1.07g
rms
Transport 5 0.03
8 0.03
40 0.003
45 0.01
70 0.01
200 0.001
Total level 1.03g
rms
Table A - 4 StorageLoader random vibration levels