6.2.2 Possible Upgrade Problems
If a power loss or a failure occurs during code download and ECC Checking, the
original FW may be intact. It is possible to restart the FW upgrade procedure.
However, if the failure occurs during flash erase or programming, the firmware will
be corrupted and a special procedure must be used to load a new code. Contact your
Technical Support Representative for assistance.
6.3 Embedded Diagnostics
The StorageLoader includes two levels of diagnostics:
The Power-On Self Test (POST) — Performs several verification and
memory tests when you power on the unit.
User Diagnostics — Selectable from the front panel
6.4 Reinstalling the Transport Lock
Before the StorageLoader is
shipped over a distance, the
transport lock must be
installed. The transport lock
will prevent damage to the
robotics during transport and
handling.
Note: Damage to the robotics
during shipping will not be
covered by warranty unless the
transport lock is installed. The
transport lock must be
removed prior to operation.
Figure 6.1 Transport lock marked with
red plastic tab
6.4.1 Transport Lock Installation Procedure
To insert the locking screw, do the following:
1. If there is a cartridge in the drive, unload the drive first.
When the loader is powered on and idle, push the Menu button and go to the
Prepare to Ship menu entry (see section 0,
2. The Maintenance Menus).
3. If there are any cartridges in the magazines, the loader will eject those
magazines and a descriptive message will be shown. Empty the magazines,
and put the magazines back in place.
4. If the magazines are empty, only the right magazine will be ejected and a
descriptive message will be shown.