User manual
Table Of Contents
- 1. About This Manual
- 2. General Information
- 3. Installation
- 3.1 Performing the Installation
- Step 1. Unpacking the StorageLoader
- Step 2. Installing the StorageLoader in a Rack
- Installing the Rack Mounting Kit
- Installing the “Rail Left Assembly”
- Installing the “Rail Right Assembly”
- Mounting the StorageLoader to the Rack
- How to dismount the StorageLoader from the rack
- Step 3. Connecting Power Cable
- Step 4. Removing the Transport Lock
- Step 5. Running Power-On Selftest
- Step 6. Setting the SCSI Address
- Step 7. Connecting the SCSI Bus Cable
- Step 8. Connecting the Ethernet Connector
- Step 9. Restarting Your System
- Step 10. BCR: Labelling of cartridges
- Step 1. Unpacking the StorageLoader
- 3.1 Performing the Installation
- 4. Operation and Configuration
- 1.
- 5. Remote Management
- 6. Maintenance
- 7. Troubleshooting
- Appendix A – Specifications
- Appendix B – Spare parts/Accessories
- Appendix C – Field Replacement Units (FRUs)

Tandberg Data Maintenance
firmware file is located and start the flash operation.
5.
6. As data transfer starts, the StorageLoader displays
this message:
Flash Firmware
SCSI Update:
Transferring Data
7. When the FW image file has been downloaded, the
loader checks the integrity of the FW image while
displaying this message:
Flash Firmware
SCSI Update:
Checking ECC
8. Once the code is approved the loader starts the erase
and reprogram operation while displaying this
message:
Flash Firmware
SCSI Update
Reprogramming
Do not interfere!
During the Erase part of the reprogramming cycle,
the Amber LED is lit to warn against interference.
The erase operation takes less than 20 seconds.
During the Programming part of the reprogramming
cycle, the Green LED flashes in addition to the
Amber LED being lit. The programming operation
takes less than one minute.
9. When reprogramming is completed, the loader will
do a normal reboot
If the firmware upgrade operation fails during point 8 due to a power shut-down or
similar, the loader may require service.
To verify that the FW version in the loader is correct, enter the view data menu.
Select the “Autoloader Info” and from there the “Loader Firmware Revision” entry
to see the revision number.
StorageLoader Installation and User Manual 49