User manual

Table Of Contents
Tandberg Data Operation and Configuration
Prepare to Ship When selected the robotics will be positioned for installation
of the locking screw.
It will eject the Right magazine to facilitate the installation.
It will also eject the left magazine if it contains one or more
cartridges. The Loader cannot be safely shipped with
cartridges in the magazines
This option must be executed before the loader is prepared
for transport by inserting the Locking Pin. (See chapters
3.1,
Performing the Installation and 6.4, Reinstalling the
Transport Lock
.)
Clean Drive Performs a drive clean provided a slot is reserved for a
cleaning tape and a cleaning tape is present
Restore default Sets the loader settings to their factory default values.
Reset Web
Password
Deletes the web passwords. This is useful when the password
is lost.
Reboot Performs a hard reset of the loader.
4.6.2 The Diagnostics Menu
Item name Description
System test Starts a test where cartridges are moved randomly between
magazine slots and between the drive and the magazines.
Move medium test Starts a test where cartridges are moved randomly between
magazine slots. The drive is excluded.
Move to pos. test Starts a test where the robotic is moving between positions
without moving any cartridges
Hardware test Runs a test of the loader hardware, including the Loader
internal cabling.
4.6.3 Set Password
Item name Description
Set Password Allows the operator to set a four-digit password protection
for the menu system. The default password is <0000>,
meaning the password is disabled.
WARNING: If you set a password, make sure you do not forget it. If you do, it can only be
cleared with assistance from Tandberg Data technical support or by a qualified service
technician.
4.7 Cartridge Handling
4.7.1 Cartridge Slot Numbers
The cartridge slots have been given numbers as follow: (see also Figure 2.3 Internal
components of the StorageLoader)
34 StorageLoader Installation and User Manual