User manual

Table Of Contents
Tandberg Data Operation and Configuration
4.4 Setup Menu
To enter this menu, scroll to the Setup item in the Main Menu and press the Select
button. The loader enters the busy state when this menu is selected.
Item name Description
StorageLoader setup This menu item gives access to the StorageLoader setup
menu.
SCSI setup This menu item gives access to the SCSI bus setup menu.
Remote
Management setup
This menu item gives access to the Remote Management
setup menu. It allows the operator to enable, disable and
configure the Loader Web interface.
4.4.1 StorageLoader setup
The numbers of selectable values for each StorageLoader setting are listed in the
following table.
Item name Legal values. Default value
Cleaning Slot Legal Slot ID 1..8 or 0 = not
selected.
0 = not selected
Barcode scan* Enabled, Disabled Enabled
Audible Alarm Enabled, Disabled Disabled
* Can be enabled only if a barcode scanner is installed. The barcode of the cartridge in each
occupied magazine slot and in the drive (if any) will then be scanned during the Inventory
process.
4.4.2 SCSI Setup
The SCSI setup menu allows selection of SCSI addresses for the internal drive. In
addition, the SCSI bus Parity can be enabled or disabled. Because of the SCSI
protocol, the values selected will only take effect after the next Reset of the Loader
and Drive.
Item name Legal values. Default value
Drive SCSI ID Legal SCSI ID: 00..15 05
Loader Personality AT1280-1R VS160
AT3200-1R LTO2
StorageLoader
StorageLoader
4.4.3 Remote Management setup
The Remote management setup menu allows enabling, configuration and access
control to the Loader via the Loader’s Remote Management Web interface. The
30 StorageLoader Installation and User Manual