- Step 1. Unpacking the StorageLoader
- 3.1 Performing the Installation
- 4. Operation and Configuration
- 1.
- 5. Remote Management
- 6. Maintenance
- 7. Troubleshooting
- Appendix A – Specifications
- Appendix B – Spare parts/Accessories
- Appendix C – Field Replacement Units (FRUs)

Tandberg Data Operation and Configuration
The Map of the cartridges has the following symbols:
1. A “?” when status is unknown and Inventory is still running.
2. A number indicates a slot occupied by a cartridge (figure 2.3 shows how the
cartridge slots are numbered in the magazines)
3. Underscore line indicates an empty slot
4. ‘C’ indicates that a Cleaning Cartridge occupies the slot.
The line below the map on the default screen gives the drive status. The drive status
displayed is drive dependent.
Menu button
Soft Label
Robot operation status
Idle Menu
Line 2
Map: __3_5_7_
Drive Empty
Figure 4.3 The Default screen
The robot operation status has the following options:
1 Idle The loader is idle
2 Fetching The loader is moving a cartridge from a magazine slot or from
the drive to the robot.
3 Stowing The loader is moving a cartridge from the robot to a magazine
slot or to the drive.
4 Moving The loader is moving the robot.
Table 4-1 Robot Operation Statuses
22 StorageLoader Installation and User Manual