Datasheet

APRIL 2007 STORAGELOADER 2U LTO
61
SETTING CONFIGURATION OPTIONS
6.
6.6.
6. Press OK.
7.
7.7.
7. Press Back (as needed) to return to the Home screen.
The Home screen now indicates that the library is operating in Sequential
Mode by the following changes.
Lib (Library) is replaced with Seq (Sequential).
D-1 (Drive-1) and D-2 (Drive-2) are replaced with A-1 and A-2
(indicating autoload function).
SETTING UP AUTOMATIC TAPE DRIVE CLEANING
The Autoclean option enables the library to automatically perform tape drive
cleaning without operator intervention. When Autoclean is enabled, the
library monitors the cleaning requirements of the tape drive(s). When a tape
drive indicates it needs cleaning, the library loads the cleaning cartridge into
the tape drive. After the cleaning cycle is complete, the tape drive unloads and
ejects the cleaning cartridge, and the library resumes operation.
Note: You do not have to use the library’s Autoclean option to clean the tape
drive(s). You can choose from several other cleaning methods, including
using your backup application’s cleaning function and using commands
available through the operator panel. See page 130 for information about
these cleaning alternatives.
Setting up automatic tape drive cleaning involves two procedures:
Activating the cleaning cartridge cell
Enabling the Autoclean option
TANDBERG DATA
StorageLoader 2U LTO
Seq
A-2
A-1
:
:
:
Idle
No Tape
No Tape
Move Lib Maint Drive
!
! !
! Important
If you plan to use automatic cleaning, the cleaning cartridge
should be stored in:
Slot/Cell 2—if the I/E Port is enabled
Slot/Cell 1—if the I/E Port is disabled
If your backup application has a cleaning option, be sure to turn
that option OFF.