Datasheet

240
PRODUCT MANUAL 1016988
APPENDIX E—ERROR MESSAGES
.
Table E-1 Library error messages
Error Message Description Corrective Action
Auto Cleaning The tape drive is performing
an automatic cleaning of the
tape drive using the cleaning
cartridge in the fixed
cleaning cell.
No action necessary.
Bad Cleaning Tape The tape drive has
determined that the
cleaning cartridge is not the
proper type for this tape
drive.
Replace the cleaning cartridge with one that is
compatible with this tape drive.
Use only LTO cleaning cartridges with LTO tape
drives.
Bad Configuration Configuration of drives does
not match drives found in
library.
1. Verify that the tape drive settings in the “Drive
configuration” menu match the type of
drive(s) installed.
See: “Reconfiguring the Library” on
page 176.
2. Check the ADI interface cabling and
configuration.
See “Connecting to SCSI” on page 17.
3. Verify that the tape drive is operating
correctly.
See: “Tape Drive Troubleshooting” on
page 200.
Bad Download An error occurred during a
firmware upload to the
library.
1. Verify that you loaded the correct code. Do
not load firmware from one model of library
or library into another.
2. Reset the library (see page 136) and reload
the firmware.
If the error persists, contact Technical Support
(see page iii) or your service provider.
Bootblock An error occurred during
firmware programing of the
library.
1. Verify that you loaded the correct code. Do
not load firmware from one model of library
or library into another.
2. Reset the library (see page 136) and reload
the firmware.
If the error persists, contact Technical Support
(see page iii) or your service provider.
Busy The library is executing a
command issued from the
backup application when a
command is issued from the
operator panel.
Wait until the library has finished its current
operation, and then retry the requested
operation.
Cartridge Misloaded A cartridge was incorrectly
loaded into the library.
Reload the cartridge. See “Inserting and Moving
Cartridges” on page 118.