Datasheet

180
PRODUCT MANUAL 1016988
CHAPTER 7—MAINTENANCE
2.
2.2.
2. Insert the tip of a small flat-blade screwdriver into the bottom of the small
slot and gently lift up to disengage the locking mechanism (see Figure 7-15).
Each side of the library has an access slot—one for each magazine. The
magazine will disengage and move a short distance out of the library.
Note: Use caution handling a magazine that is loaded with cartridges. Each
cartridge weighs over ½ lb. (0.24 kg) each. Fully loaded, each
magazine will weigh approximately 5.0 lbs. (2.4 kg).
3.
3.3.
3. Pull the magazine straight out of the library. Use caution not to move the
magazine up or down, or from side to side as you pull it out of the library. This
could cause damage to components inside the library.
REMOVING A CARTRIDGE FROM THE TAPE DRIVE
If a cartridge is loaded in a tape drive when power to the library fails and you
need to remove that cartridge, you must first remove the tape drive from the
library (see “Installing or Replacing a Tape Drive” on page 163 for
instructions).
If the library’s power supply failed, you can attach the tape drive to another
power source, such as an available power connector in a server and use the
tape drive’s unload button to remove the cartridge.
If a general power failure occurred, contact Tandberg Data Corporation
Technical Support (see page iii) for information about removing the
cartridge from the tape drive manually.
Figure 7-15 Manual magazine release
Use caution not to insert tip
of screwdriver too far or you will
damage components inside the library.