CHAPTER 5—OPERATING THE LIBRARY
The Clean Drive option allows you to select any slot/cell as the source for a
cleaning cartridge, including an I/E Port. Determine the location of your
cleaning cartridge, and then proceed.
When a tape drive requires cleaning:
1.
1.1.
1. At the Home screen, press Maint.
If necessary, enter the operator panel password (see page 78).
2.
2.2.
2. Press until the selection arrow ( ) points to Cleaning Options.
Cleaning
Cartridge
Condition Description
Not stored in
library
Cells all occupied Use the Export command to remove a
cartridge from the library, as described on
page 124. Before closing the I/E Port door,
insert the cleaning cartridge.
Cells not all
occupied
Load the cleaning cartridge into an enabled
I/E Port, and then select it as the “source” in
Step 4 below.
Stored in
library
I/E Port enabled Store in Slot/Cell 2
I/E Port disabled Store in Slot/Cell 1
Maintenance
Library Maintenance
Drive Maintenance
Cleaning Options
System Reset
USB Options
Select Back