Datasheet
112
PRODUCT MANUAL 1016988
CHAPTER 4—USING THE REMOTE MANAGEMENT UTILITY
Update from the USB port
Lib Test Library Test – Use this option to run test’s on the library. None of
these tests will write data to tape, but some of them will load cartridges into
and out of the tape drive(s). The following tests are available:
To stop a test in progress, click the Stop the Test button. If you press this
button, the library completes the current action, and then stops. For example,
if the library loaded a cartridge into a tape drive, it unloads it and returns it to
its slot before stopping the test.
Test Description
Basic Load/Unload Loads cartridges into and out of the tape drive(s)
Random Slot to Slot
Move
Moves cartridges from slot to slot in random order (the
library must have empty slots to conduct this test)
Simple Positioning Moves the robot sequentially around the library starting
at slot 1
Harder Positioning Moves the robot randomly around the library and
positions it at various locations