Instructions

tams elektronik
!
!
PZS-2 English
Performing a visual check
Perform a visual check after the assembly of the module and remove
faults if necessary:
Remove all loose parts, wire ends or drops of solder from the PCB.
Remove all sharp wire ends.
Check that solder contacts which are close to each other are not
unintentionally connected to each other. Risk of short circuit!
Check that all components are polarised correctly.
When you have remedied all faults, go on to the next part.
7. Functional test
It is recommended to test the basic functioning of the module before
installing it into the layout.
Connect a bulb to the connections 5 and 6 of the PZS-2.
Connect the driving transformer to the module, namely
the driving transformer´s earth connection to the connection 3 of
the PZS-2 and
the driving transformer´s "+" to the connection 11 of the PZS-2.
Turn on the controller of the driving transformer.
Connect the power supply for the shuttle-train control to the
connections 1 and 10 of the PZS-2 and switch it on.
Do not use the driving transformer for supplying the PZS-2.
The lamps should start to light up slowly. With it, the functional test is
completed. In case the lamp does not light up, check the connections.
Caution:
If a component gets too hot, disconnect the module from the power
supply mmediately. Possible short circuit! Check the assembly!
Page 23