When connected to DC voltage, one or both LEDs do not light
according to polarity.
Possible cause: One or both LEDs are not soldered in accordance
with the polarity shown on the board. à Change the installation
direction.
Hotline
If problems with your module occur, our hotline is pleased to help you
(mail address on the last page).
Repairs
You can send in a defective module for repair (address on the last
page). In case of guarantee the repair is free of charge for you. With
damages not covered by guarantee, the maximum fee for the repair is
the difference between the price for the ready-built module and the kit
according to our valid price list. We reserve the right to reject the
repairing of a module when the repair is impossible for technical or
economic reasons.
Please do not send in modules for repair charged to us. In case of
warranty we will reimburse the forwarding expenses up to the flat rate
we charge according to our valid price list for the delivery of the
product. With repairs not covered by guarantee you have to bear the
expenses for sending back and forth.