User manual
tams elektronik
English FI-1
4. Operation overview
The function inverter has to be connected between the LED and the
function output of the locomotive or function decoder and inverts the
polarity of the decoder connections. Examples of use: 
Red-yellow or red-white dual-LEDs are  suitable as  the  front or  back
lighting of model railway locomotives or carriages. Often they have a
common   cathode   for   both   colours.   For   that   reason   they   cannot   be
connected   directly   to   the   function   outputs   of   vehicle   decoders,   as
decoders´ return conductors have a reverse polaritiy (+). These dual-
LEDs can be connected via a function inverter to the decoder outputs. 
The cathodes (-) of LED-lighting in standard control cab coaches are
often mounted with a common connection to earth. For that reason
they cannot be connected directly to a vehicle decoder when mounting
a decoder. Instead of altering the  diodes you  can mount  a function
inverter. 
5. Technical specifications
Supply voltage Digital voltage of the decoder
Current consumption (without 
connected LEDs) approx.
0,1 mA
Max. total current  30 mA
Protected to IP 00
Ambient temperature in use 0 ... +60 °C
Ambient temperature in storage -10 ... +80 °C
Comparative humidity allowed  max. 85 %
Dimensions of the PCB (approx.) 7,5 x 6,5 x 2 mm
Weight of the PCB  0,1 g
Page 20