7.2. Connecting the SAS
Connection diagram
1
First connect the three programming push-buttons, the servo and the
voltage supply to all versions of the SAS.
programming push-button "SET": black push-button
programming push-button 1 and 2 (connections E1 and E2): red
black push-buttons
Then check the servo and set the angle of rotation. Connect (with SAS-
3) the HST-PCB or a points decoder if necessary after having
performed a test and set the servo.
Attention:
When a component gets too hot, disconnect the module from the
voltage supply immediately. Risk of short circuit! Check the assembly.
Connect the functional model only after having performed a test and
set the servo. That is the only way to reliably avoid damages on the
model.
Do not set the SAS-3 while the HST PCB is connected. Risk of short
circuit! Disconnect the HST PCB if necessary or switch off the track
voltage.