Sequence for the connection example on page 48
After module 1 is switched on, outputs 1 to 14 (and the LEDs or light
bulbs connected to them) are switched on one after the other. At the
same time as the LEDs/lights on output 9, module 2 is switched on and
with the LEDs/lights on output 14, module 3 is switched on. When
output 13 of module 2 is switched on, module 4 is also switched on.
Since each LC-NG module is connected directly to the power supply,
any number of modules can be cascaded.