Performing a visual check
Perform a visual check after the assembly of the module and remove
faults if necessary:
Remove all loose parts, wire ends or drops of solder from the PCB.
Remove all sharp wire ends.
Check that solder contacts which are close to each other are not
unintentionally connected to each other. Risk of short circuit!
Check that all components are polarised correctly.
When you have remedied all faults, go on to the next part.
7. Connecting the LC-NG modules
In this section you will find information that applies to all LC-NG
modules. Please also note the section in Part B of the instructions,
where the special features of the respective version, especially the
connection assignment, are shown.