Instructions

Table Of Contents
tams elektronik
LC-Modules Next Generation English
11. LC-NG-11 "Flickering flames & candle lights"
11.1. Mode of operation
After switching on the module, i.e. as soon as the switching input is
connected to earth, the outputs are switched on in pairs. This simulates
the flare-up of the fire.
While the module is switched on, the LEDs or small lamps at the
outputs flicker in the manner typical of candles or fire.
After the module is switched off, i.e. as soon as the switching input has
been disconnected from earth, the outputs are switched off one after
the other in pairs to simulate the fire burning up.
Use of the switching input
Switching input Effect
Switch closed
(switched to earth)
"Start phase": The outputs are switched on
in pairs one after the other.
Switch open "Closing phase": The outputs are switched
off in pairs one after the other.
Settings on the trim potentiometer
You can change the length of the pauses between switching the output
pairs on and off at the trim potentiometer. The length of the pauses is
shorter in the left-hand direction of rotation* and longer in the right-
hand direction of rotation.
Note: The position of the trim pot has no influence on the sequence
after the start phase or before the end phase.
* Note: If the trim potentiometer is set to the left stop, the module goes into test mode when it
is switched on. You must therefore turn the potentiometer a little to the right to set the smallest
possible pause length after you have set it to the left stop.
Page 81