English LC-Modules Next Generation
6. LC-NG-06 "Emergency vehicles"
6.1. Mode of operation
The outputs of the LC-NG-06 control the warning lights of (several)
emergency vehicles and a siren. The sound of the siren is stored on the
IC. The outputs can be set (together) either as simple flashing lights
(for older emergency vehicles) or as flashlights (for modern emergency
vehicles).
Note on the stored sound: The LC-NG module is not intended as a sound module, the stored
sound is accordingly simple.
Use of the switching input
Switching input Effect
Switch closed
(switched to earth)
Start of sequence
Switch open
End of sequence
(after approx. one second)
Note: The programme sequence is only started or ended via the switch input if the trimmer
potentiometer is not set to the right stop (→ following paragraph).
Settings on the trim potentiometer
You can set the start mode at the trimmer potentiometer. When set to
"right stop", the sequence is started as soon as the module is supplied
with power - regardless of whether the switching input is open or
closed. With any other potentiometer position*, the sequence is only
started after the input has been connected to earth. You can thus start
the sequence with a switch or by another circuit.
* Note: If the trim potentiometer is set to the left stop, the module goes into test mode when it
is switched on. You must therefore turn the potentiometer a little to the right after setting it to
the left stop.