Connection to the power supply
Connect the double flashlight according to the figures and the list, to
the power supply. When connecting the PCB to (analogue) a.c. voltage,
the connections´polarity is not relevant. When connecting the PCB to
(analogue) d.c. voltage, you have to observe the connections´ polarity.
Power supply
d.c. voltage a.c. voltage
GND  -
Polarity not relevant
12V (WBA-1) 
Uin (WBA-2) 
U+/~ (WBA-3)
+
Use in non digital D.C. layouts
The LEDs shine in one direction of travel only
when the double flashlight is used in vehicles
run  in railway  layouts  supplied by (analogue)
d.c.   voltage.   If   they   should   work   in   both
directions of travel, mount an additional brigde
rectifier   (e.g.  item   no.   83-19100-10,  not
included in delivery) according to the figure.
Connection to a decoder output
Connect   the   connection  "GND"  to   the   output   of   the   locomotive   or
function decoder you intend to switch the double flashlight. Connect the
connection "12V", "Uin" or "U+/~" to the return conductor of the output
or the return conductor for all outputs.
Page 15
Transformer
Rectifier