9. Check list for troubleshooting
 Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more components are soldered incorrectly.
à In case you   have  mounted  the  module from   a kit,   perform  a
visual check (à  section  6.)   and if   necessary,  remedy the  faults.
Otherwise send in the module for repair.
 The lamps connected to the module do not light. 
Possible cause: one or more components are soldered incorrectly.
à Perform a visual check. 
Possible cause: A switch connected to the module is closed. à Check
the position of switches.
Possible   cause:   The   bulbs   or   LEDs   are   defective.   Check   the
bulbs / LEDs.
Possible cause: The LEDs are connected falsely polarized.   Check
the LEDs´polarity.
Possible cause: One  or more outputs have been damaged  due to
overload.  Send in the module for repair.
Possible cause: With a serial connection too many LEDs have been
switched in series.  Decrease the number of LEDs or increase the
voltage supply.