User manual

tams elektronik
English WIB-33.2
Settings for the orientation light
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Value in CV#115
0 32
Function keys
for activating
the
orientation
light
118 41 1 ... 255 F1 F5 1
F2 F6 2
F3 F7 4
F4 F8 8
F0 F9 16
F10 32
F11 64
F12 128
It is possible to activate the function with several function keys.
Remark: If you want to assign the function keys F5 to F12 to this function you have to set the
value "32" in CV#115 first.
Factory settings: The orientation light is activated with F3.
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Brightness of
the orientation
light
119 42 1 ... 255
(16)
The lower the input value the
brighter is the orientation
light.
Settings for the fluorescent tubes
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Simulation
of a defective
fluorescent
tube
125 47 0 ... 255 (0) LED1 1
LED2 2
LED3 4
LED4 8
LED5 16
LED6 32
LED7 64
LED8 128
Factory settings: The simulation of a defective fluorescent tube is defined for none of the eight
LEDs.
Remark: The setting in CV#125 only takes effect when in CV#115 the fluorescent tube
simulation has been activated (factory settings fluorescent tube simulation deactivated).
Duration of switching on the fluorescent tubes
LED1 | LED2 126 48 0 ... 255 (52) no flickering 0
LED3 | LED4 127 49 0 ... 255 (35) short flickering 1
LED5 | LED6 128 50 0 ... 255 (83) ...
LED7 | LED8 129 51 0 ... 255 (71) long flickering 15
You can choose a value between 0 and 15 for each output. Enter the value directly for the
even LEDs, for the odd LEDs multiply the value by 16.
Example: For LED1 value "2" and for LED2 value "14"à Input value: 46 (=2x16 + 14)
Remark: The settings in CV#125 to 129 only take effect when in CV#115 the fluorescent tube
simulation has been activated (in factory settings: fluorescent tube simulation deactivated).
Setting the kicking time for AUX1 and AUX3
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Kicking time
AUX1 | AUX3
124 46 0 ... 255 (0) = length of time the full
voltage is applied, before
being reduced to the value set
in CV#63 or 64. The max.
time of 10 seconds
corresponds to the value "15".
You can choose a value between 0 and 15 for each output. Enter the value directly for AUX1
and for AUX3 multiply the value by 16.
Example: For AUX1 value "7" and for AUX3 value "3"à Input value: 55 (=7 + 3x16)
Choosing presets
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Choosing
presets
130 52 -- Preset 0 0
Preset 1 1
Preset 2 2
Preset 3 3
Remark: A set value in this variable can be taken over into operation when you proceed as
follows:
1. Performing a reset (i.e. entering an optional value in CV#8).
2. Supplying the vehicle shortly with power (i.e. setting the vehicle shortly onto the powered layout).
3. Entering in CV#130 the desired value, afterwards altering the address and making further
modification, if necessary.
Page 18