Manual WIB-33.2 Carriage lighting with integrated function decoder Colour of lighting: warm white tro ni k Item no.
English WIB-33.2 Table of contents 1. Getting started............................................................................3 2. Safety instructions.......................................................................4 3. Safe and correct soldering...........................................................5 4. Operation overview.....................................................................6 5. Technical specifications...............................................................
WIB-33.2 English 1. Getting started How to use this manual This manual gives step-by-step instructions for safe and correct fitting and connecting of the module, and operation. Before you start, we advise you to read the whole manual, particularly the chapter on safety instructions and the checklist for trouble shooting. You will then know where to take care and how to prevent mistakes which take a lot of effort to correct. Keep this manual safely so that you can solve problems in the future.
English WIB-33.2 2. Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones.
WIB-33.2 English 3. Safe and correct soldering ! Caution: Incorrect soldering can cause dangers through fires and heat. Avoid these dangers by reading and following the directions given in the chapter Safety instructions. ta m k ni tro el ek Use a small soldering iron with max. 30 Watt. Keep the soldering tip clean so the heat of the soldering iron is applied to the solder point effectively. Only use electronic tin solder with flux.
English WIB-33.2 4. Operation overview Possibilities of use The carriage lighting WIB-33.2 can be used in digital layouts driven in DCC or Motorola format as well as in analogue model railroad layouts. For the power supply digital boosters or analogue a.c. or d.c. transformers can be used. Design of the PCB The carriage lighting WIB-33.2 have inserted 8 warm white LEDs.
WIB-33.2 English Operation in analogue mode The carriage lighting WIB-33.2 can also be used in analogue model railway layouts. When putting the vehicle on the rails the decoder recognizes automatically if it is run in analogue or digital mode and sets the corresponding operation mode. The automatic recognition of the analogue mode can be switched off. Switching the LEDs and the function outputs on or off is not possible in analogue mode.
English WIB-33.2 of 16 V or two goldcaps with a minimal voltage sustaining capability of 5,5 V. In order to supply the three function outputs of the decoder you can connect a second additional external bridging capacitor. It is not possible to use goldcaps here, as the minimal voltage sustaining capability is 25 V or 35 V (when connecting the PCB to analogue a.c. voltage). Feedback with RailCom RailCom is a log for bi-directional communication in digital model railway layouts controlled in DCC-format.
WIB-33.2 English 5. Technical specifications Data format DCC, Motorola Adress range MM: 1020 DCC: 2040 Hint: The adress range to be used also depends from the control unit. Speed levels (DCCFormat) 14, 28 or 128 Feedback log RailCom Supply voltage Digital voltage of the central unit or analogue d.c. or a.c. voltage Minimum supply voltage approx. 7 V (yellow LEDs) 8 V (white LEDs) Maximum supply voltage 24 Volt Current consumption at 50 mA maximum brightness (without connected loads approx.
English WIB-33.2 6. Mounting the carriage lighting 6.1. Overall view power supply E(+) E(-) external bridging capacitor AUX1 AUX3 decoder outputs max. current: 300 mA AUX2 decoder output for therconnection of LEDs (back lighting) max. current: 20 mA RL1 RL2 return conductor for decoder outputs AUX1 and AUX3 RL2 return conductor for decoder output AUX2 LDR1 LDR2 light depending resistor L4 ...
WIB-33.2 English 6.2. Connection to the power supply Solder the connecting wires for the power supply to the connecting points P1, P3 or P5 (from the left rail) and the connecting points P2, P4 or P6 (from the right rail). You can loop through the power supply from one PCB to the next and thus supply several carriage lighting from one current source. ! Caution: When using power transmissing couplings pay attention not to exceed the maximum current of the couplings! 6.3.
English WIB-33.2 6.5. Connecting LEDs to the output AUX2 The output AUX2 has been designed for the connection of LEDs for the back lighting. The maximum current is 20 mA. The necessary series resistors are integrated on the PCB. Solder the LEDs to the connecting points AUX2 and RL2. ! Caution: Do not connect electric bulbs to the output AUX2! These have normally a current of more than 20 mA. The output will be damaged when setting-up operation. 6.6.
WIB-33.2 English 6.8. Setting the LEDs´ brightness Instead of programming with a digital control unit you can set the LEDs´ brightness via a trim-pot (see digram in section 6.1). For setting the trim-pot use a small screw-driver. The brightness programmed via CVs or register remains active, the settings at the trim-pot only alter the brightness with a factor valid for all LEDs. 6.9. Fixing the carriage lighting After completing the connections, secure the lighting in place (eg.
English WIB-33.2 Programming with the Central Station and the Mobile Station With the Central Station or the Mobile Station of Märklin* you can program the registers, but the value to be set is limited to 80. Select the article no. 29750 from the locomotive database and program the decoder as described for this article in the Central Station´s or Mobile Station´s manual.
WIB-33.2 English Auxiliary functions Name of CVs / CV- Reg. Input value Registers no. no. (Default) Reset 8 03 0 ... 255 Remarks and Tips Settings Any input value restores the settings in state of delivery. Basic settings Name of CVs / CV- Reg. Input value Registers no. no. (Default) Configuration 29 10 0 ...
English WIB-33.2 Basic settings for the LEDs and the outputs Outputs programmed as random lights cannot be switched via function keys. function key for LDR function key for orientation light function key for AUX1 function key for AUX3 k Factory settings: Fluorescent tube simulation = "off". AUX3 = random light. Dim switch (via LDR) switches the LEDs and the devices connected to the outputs on when the limit value of the surrounding lighting is under-run.
WIB-33.2 English Dependant on the direction of motion of the LEDs and the outputs Name of CVs / CV- Reg. Input value Registers no. no.
English WIB-33.2 Settings for the orientation light Name of CVs / CV- Reg. Input value Registers no. no. (Default) Function keys for activating the orientation light 118 41 1 ... 255 Value in CV#115 0 F1 F2 F3 F4 F0 32 F5 F6 F7 F8 F9 F10 F11 F12 1 2 4 8 16 32 64 128 It is possible to activate the function with several function keys. Remark: If you want to assign the function keys F5 to F12 to this function you have to set the value "32" in CV#115 first.
WIB-33.2 English 9.
English WIB-33.2 10. Check list for troubleshooting Parts are getting too hot and/or start to smoke. ! Disconnect the system from the mains immediately! Possible cause: one or more connections are soldered incorrectly. à Check the connections. Possible cause: Short circuit. The module is connected to locomotive or carriage ground. à Check the connections. A short circuit can result in irreparable damage.
WIB-33.2 English 11. Guarantee bond For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first purchasing the product from us, a dealer or another natural or juristic person reselling or mounting the product on the basis of selfemployment. The guarantee exists supplementary to the legal warranty of merchantability due to the consumer by the seller.
WIB-33.
English ta m s el ek tro ni k WIB-33.
n n n n n n n n n ni n k n tro n n el ek Aktuelle Informationen und Tipps: Information and tips: Informations et conseils: Actuele informatie en tips: ta m s http://www.tams-online.de n n n n n Garantie und Service: Warranty and service: Garantie et service: Garantie en service: Tams Elektronik GmbH Fuhrberger Straße 4 DE-30625 Hannover fon: +49 (0)511 / 55 60 60 fax: +49 (0)511 / 55 61 61 n n n n n e-mail: modellbahn@tams-online.