User manual
!
Multi-Timer English
Performing a visual check
Perform a visual check after the assembly of the module and remove
faults if necessary:
Remove all loose parts, wire ends or drops of solder from the PCB.
Remove all sharp wire ends.
Check that solder contacts which are close to each other are not
unintentionally connected to each other. Risk of short circuit!
Check that all components are polarised correctly.
When you have remedied all faults, go on to the next part.
7. Connecting the Multi-Timer
Functional test
Especially, when you have mounted the Multi-Timer from a kit, you
should perform a functional test before mounting it in your layout.
Connect an electric bulb with a separate power supply to output 1 and
a push-button to switching input 1 as described below for operation
mode 1. Connect the Multi-Timer to the power supply.
Choose operation mode 1 (r) for testing all outputs, so do not insert a
jumper to any of the solder pins. Set a short switching time (trim-pot as
far as it will go to the left). Then check all four outputs and switching
inputs one after the other.
Caution:
When a component gets hot, disconnect the module from the power
supply immediately! Risk of short circuit! Check the assembly!
Page 49
tams elektronik