User manual
Multi-Timer English
In this operation mode the Multi-Timer can be set either to allow it to
be retriggered or not. 
To be retriggered: When the contacts of the switching input are closed
again (e.g. by activating the push-button again), before the set time
has run out, the time starts to run from scratch again. Example: When
at a set  time of  60 seconds the contacts  of the switching input  are
closed again after 30 seconds, the overall activating time is 90 seconds.
Not to be retriggered: When the contacts of the switching  input are
closed again, before the set time has run out, this has no effects. A
new switching operation cannot be released befort the set activating
time has run out. 
Application: 
You can apply the operation mode 1 for  all actions you want to be
switched on for a certain time and to be switched off automatically after
the time has run out. 
Operation mode 2 "Pulse Delay"
The delay time has to be set individually at a trim-pot for each output.
The maximum activating time is 4,5 minutes. 
Each change in state at one of the switching inputs is transmitted to the
related output with the set delay. One change in state is as well an
opening as a closing of the contacts of the switching input. A maximum
of 64 changes in state can be saved within the set time of delay. In
case  there  are more  changes of  state  within the  time of  delay, the
changes of state first executed will be deleted.
Application: 
You can apply  the   operation   mode 2 for  all   actions   that should be
executed with a time delay after a preceding occurance, e.g. opening
the level-crossing after a train has passed or setting the signal to stop
after a train has passed.
Page 39
tams elektronik