Instructions

tams elektronik
!
Multi-Timer English
5. Technical specifications
Caution:
Do not use the same transformer for the power supply of the Multi-
Timer as used for the power supply of downstream circuits or the rails.
Supply voltage 12-18 Volt
d.c. or a.c. voltage
Current consumption (approx.) 50 mA
Number of outputs
Max. switching current per output
4
1,500 mA
Number of switching inputs 4
Operation mode 1: Max. switching time approx. 4,5 Minuten
Operation mode 2: Max. delay time approx. 30 seconds
Operation mode 3:
Max. time interval to be set (.) approx. 4.5 minutes
Operation mode 4:
Max. stopping time to be set (approx.)
Max. braking / starting time (approx.)
approx. 4.5 minutes
approx. 12 seconds
Protected to IP 00
Ambient temperature in use 0 ... +60 °C
Ambient temperature in storage -10 ... +80 °C
Comparative humidity allowed max. 85 %
Dimensions of the PCB (approx.)
Dimensions including housing (approx.)
72 x 82 mm
100 x 90 x 35 mm
Weight of the assembled board (approx.)
Weight including housing (approx. )
55 g
103 g
Page 19