4.1. Operation mode 1 "Time Switch"
Use in analogue or digital layouts
The activating time has to be set individually at a trim-pot for each
output. The maximum activating time is 4,5 minutes.
After the closure of the contacts of a switching input the related output
is switched on for the set time. In order to release a switching pulse
push-buttons or comparable external circuits can be used.
In this operation mode the Multi-Timer can be set either to allow it to
be retriggered or not.
To be retriggered: When the contacts of the switching input are
closed again (e.g. by activating the push-button again), before the set
time has run out, the time starts to run from scratch again. Example:
When at a set time of 60 seconds the contacts of the switching input
are closed again after 30 seconds, the overall activating time is 90
seconds.
Not to be retriggered: When the contacts of the switching input are
closed again, before the set time has run out, this has no effects. A
new switching operation cannot be released befort the set activating
time has run out.
Application
You can apply the operation mode 1 for all actions you want to be
switched on for a certain time and to be switched off automatically after
the time has run out.