8. Check list for troubleshooting
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more components are soldered incorrectly.
à In case you have mounted the module from a kit, perform a
visual check (à section 6.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
When setting the trimming pot the relay does not switch.
Possible cause: one or more components are soldered incorrectly.
Perform a visual check.
Possible cause: The IC has been inserted into the IC-socket in the
wrong direction. The IC has consequently been destroyed and
must be replaced. (The programmed IC can only be purchased
directly from Tams Elektronik!)
During the testing run the central unit switches off.
Possible cause: one or more components are soldered incorrectly.
Perform a visual check.
Possible cause: The trimming pot is set incorrectly. Set the
trimming pot according to the section "Setting the operating point"
and repeat the test.
When the train is driving out of the loop the points are switched
incorrectly.
Possible cause: The connections X3-1 and X3-3 have been assigned
incorrectly. Interchange the connections.