8. Check list for troubleshooting
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more components are soldered incorrectly.
In case you have mounted the module from a kit, perform a
visual check ( section 6.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
The loop module does not work as intended.
Possible cause: There is no RailCom detector connected and the
connection points JP1 are not bridged. In consequence there are no
track busy messages to be sent from the inside of the loop. Bridge
the connections JP1, e.g. with the short circuit termination (jumper)
included in the package.
When coming into one of the transition zone a short circuit occurs.
Possible cause: The connecting points 5, 6 and 7 are not connected
to the rails of the transition zones the right way. Check the
connections, especially if the inner rails of both transition zones are
connected to connecting point 6.
When coming into a transition zone the locomotive stops.
Possible cause: The connecting points 5, 6 and 7 are not properly
connected to the rails of the transition zones. Check the
connections.